A Saturation Artifacts Inpainting Method Based on Two-Stage GAN for Fluorescence Microscope Images.

Micromachines (Basel)

Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China.

Published: July 2024

Fluorescence microscopic images of cells contain a large number of morphological features that are used as an unbiased source of quantitative information about cell status, through which researchers can extract quantitative information about cells and study the biological phenomena of cells through statistical and analytical analysis. As an important research object of phenotypic analysis, images have a great influence on the research results. Saturation artifacts present in the image result in a loss of grayscale information that does not reveal the true value of fluorescence intensity. From the perspective of data post-processing, we propose a two-stage cell image recovery model based on a generative adversarial network to solve the problem of phenotypic feature loss caused by saturation artifacts. The model is capable of restoring large areas of missing phenotypic features. In the experiment, we adopt the strategy of progressive restoration to improve the robustness of the training effect and add the contextual attention structure to enhance the stability of the restoration effect. We hope to use deep learning methods to mitigate the effects of saturation artifacts to reveal how chemical, genetic, and environmental factors affect cell state, providing an effective tool for studying the field of biological variability and improving image quality in analysis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11279111PMC
http://dx.doi.org/10.3390/mi15070928DOI Listing

Publication Analysis

Top Keywords

saturation artifacts
16
saturation
4
artifacts inpainting
4
inpainting method
4
method based
4
based two-stage
4
two-stage gan
4
gan fluorescence
4
fluorescence microscope
4
microscope images
4

Similar Publications

In this work, we introduce spatial and chemical saturation options for artefact reduction in magnetic resonance fingerprinting (MRF) and assess their impact on T and T mapping accuracy. An existing radial MRF pulse sequence was modified to enable spatial and chemical saturation. Phantom experiments were performed to demonstrate flow artefact reduction and evaluate the accuracy of the T and T maps.

View Article and Find Full Text PDF

Purpose: To develop and evaluate a physics-driven, saturation contrast-aware, deep-learning-based framework for motion artifact correction in CEST MRI.

Methods: A neural network was designed to correct motion artifacts directly from a Z-spectrum frequency (Ω) domain rather than an image spatial domain. Motion artifacts were simulated by modeling 3D rigid-body motion and readout-related motion during k-space sampling.

View Article and Find Full Text PDF

Lipid nanoparticles formed with copolymers are a new and increasingly powerful tool for studying membrane proteins, but the extent to which these systems affect the physical properties of the membrane is not completely understood. This is critical to understanding the caveats of these new systems and screening for structural and functional artifacts that might be caused in the membrane proteins they are used to study. To better understand these potential effects, the fluid properties of dipalmitoylphosphatidylcholine lipid bilayers were examined by electron paramagnetic resonance (EPR) spectroscopy with spin-labeled reporter lipids in either liposomes or incorporated into nanoparticles with the copolymers diisobutylene-maleic acid or styrene maleic acid.

View Article and Find Full Text PDF

Purpose: Evaluate the feasibility of quantification of Relaxation Along a Fictitious Field in the 2nd rotating frame (RAFF2) relaxation times in the human myocardium at 3 T.

Methods: mapping was performed using a breath-held ECG-gated acquisition of five images: one without preparation, three preceded by RAFF2 trains of varying duration, and one preceded by a saturation prepulse. Pixel-wise maps were obtained after three-parameter exponential fitting.

View Article and Find Full Text PDF

Prospective acceleration of whole-brain CEST imaging by golden-angle view ordering in Cartesian coordinates and joint k-space and image-space parallel imaging (KIPI).

Magn Reson Med

November 2024

Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, College of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou, China.

Purpose: To prospectively accelerate whole-brain CEST acquisition by joint k-space and image-space parallel imaging (KIPI) with a proposed golden-angle view ordering technique (GAVOT) in Cartesian coordinates.

Theory And Methods: The T-decay effect will vary across frames with variable acceleration factors (AF) in the prospective acquisition using sequences with long echo trains. The GAVOT method uses a subset strategy to eliminate the T-decay inconsistency, where all frames use a subset of shots from the calibration frame to form their k-space view ordering.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!