A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Investigation of the Mechanical Strength of Artificial Metallic Mandibles with Lattice Structure for Mandibular Reconstruction. | LitMetric

Mandibular reconstructive surgery is necessary for large bone defects. Although various reconstruction methods have been performed clinically, there is no mandibular reconstruction method that meets both sufficient strength criteria and the patient's specific morphology. In this study, the material strength of the cylindrical lattice structures formed by electron-beam melting additive manufacturing using titanium alloy powder was investigated for mandibular reconstruction. The virtual strengths of 28 lattice structures were compared using numerical material tests with finite element method software. Subsequently, to compare the material properties of the selected structures from the preliminary tests, compression test, static bending test and fatigue test were conducted. The results showed that there were correlations with relative density and significant differences among the various structures when comparing internal stress with deformation, although there was a possibility of localized stress concentration and non-uniform stress distribution based on the lattice structure characteristics. These results suggest that the lattice structure of body diagonals with nodes and a cell size of 3.0 mm is a potential candidate for metallic artificial mandibles in mandibular reconstruction surgery.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11278567PMC
http://dx.doi.org/10.3390/ma17143557DOI Listing

Publication Analysis

Top Keywords

mandibular reconstruction
16
lattice structure
12
lattice structures
8
lattice
5
mandibular
5
reconstruction
5
investigation mechanical
4
mechanical strength
4
strength artificial
4
artificial metallic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!