A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Health Technology Assessment of Cardiopulmonary Bypass Circuit with and without Phosphorylcholine Coating: A Retrospective Study on Safety and Efficiency in Cardiac Surgery. | LitMetric

Background: Phosphorylcholine has emerged as a potential adjunctive agent in cardiopulmonary bypass (CPB) circuits. Phosphorylcholine serves as a coating for the CPB circuit, potentially enhancing biocompatibility and reducing thrombotic events. However, its impact on specific patient populations and procedural outcomes remains underexplored.

Materials And Methods: In this retrospective study, we analyzed data from 60 patients who underwent cardiac surgery with CPB, comprising 20 cases each of coronary artery bypass grafting (CABG), mitral valve repair, and aortic valve replacement. The patient cohort was divided into two groups-30 patients whose CPB circuits were coated with phosphorylcholine (phosphorylcholine-coated group) and 30 patients who did not receive phosphorylcholine supplementation or circuit coating. Both groups underwent surgery with identical CPB circuit designs. We assessed the absence of adverse events, safety, and efficacy parameters, including blood loss, clotting, and the structural integrity of the CPB circuit. Additionally, we measured changes in mean albumin levels (g/dL), mean platelet counts (×10/L), and antithrombin III (ATIII) levels before and after CPB.

Results: The retrospective analysis revealed an absence of adverse events in both groups. In the phosphorylcholine-coated group compared to the non-phosphorylcholine-coated group, there was a notable difference in the delta change in mean albumin levels (0.87 ± 0.1 vs. 1.65 ± 0.2 g/dL, -value 0.021), mean platelet counts (42.251 ± 0.121 vs. 54.21 ± 0.194 × 10/L, -value 0.049), and ATIII levels (16.85 ± 0.2 vs. 31.21 ± 0.3 -value 0.017). There was a notable reduction in the perioperative consumption of human complex units after CPB (3 vs. 12, -value 0.019).

Conclusions: Both groups, phosphorylcholine and non-phosphorylcholine, demonstrated the absence of adverse events and that the systems are safe for iatrogenic complication. Our findings suggest that the use of phosphorylcholine coating on the CPB circuit, in the absence of supplementary phosphorylcholine, in cardiac surgery is associated with favorable changes in mean albumin levels, mean platelet counts, and ATIII levels. Further research is warranted to elucidate the full extent of phosphorylcholine's impact on patient outcomes and CPB circuit performance.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11277647PMC
http://dx.doi.org/10.3390/life14070851DOI Listing

Publication Analysis

Top Keywords

cpb circuit
20
cardiac surgery
12
absence adverse
12
adverse events
12
albumin levels
12
platelet counts
12
atiii levels
12
cpb
9
cardiopulmonary bypass
8
phosphorylcholine
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!