Influence of Thermal Treatment on the Chemical and Structural Properties of Geopolymer Gels Doped with NdO and SmO.

Gels

Department of Atomic Physic, Vinča Institute of Nuclear Sciences, National Institute of the Republic of Serbia, University of Belgrade, Mike Petrović Alasa 12-14, Vinča, 11000 Belgrade, Serbia.

Published: July 2024

In this research, the influence of the thermal treatment of geopolymer gels at 300 °C, 600 °C and 900 °C when incorporated with 5% rare earth elements (REEs) in the form of (GP-Sm) SmO and (GP-Nd) NdO was investigated. Changes in the chemical and structural properties of the geopolymer gels during thermal treatment for 1 h were monitored. Physico-chemical characterization was performed using the following methods: diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS), scanning electron microscopy with energy dispersive spectrometry (SEM-EDS), and X-ray photoelectron spectroscopy (XPS). Besides the characterization of the fundamental properties, some practical macroscopic properties were analyzed as well: sorptivity, open porosity, and Archimedean density. The stretching vibrations of Nd-O-Si and Sm-O-Si were confirmed at a value of around 680 cmand an Nd-O-Si absorption band at a higher value, together with the most dominant band of Si-O stretching vibration similar for all the samples. No significant chemical changes occurred. Structural analysis showed that for GP-Nd, the largest pore diameter was obtained at 900 °C, while for GP-Sm, the largest pore diameter was obtained at 600 °C. EDS confirmed the amount of dopant to be about 5%. X-ray photoelectron spectroscopy showed that for GP-Nd, the ratio of Si and Al changed the most, while for GP-Sm, the ratio of Si and Al decreased with increasing temperature. The contributions of both dopants in the GP-gel structure remained almost unchanged and stable at high temperatures. The atomic percentages obtained by XPS analysis were in accordance with the expected trend; the amount of Si increased with the temperature, while the amount of Al decreased with increasing temperature. The sorptivity and open porosity showed the highest values at 600 °C, while the density of both geopolymers decreased linearly with increasing temperature.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11275300PMC
http://dx.doi.org/10.3390/gels10070468DOI Listing

Publication Analysis

Top Keywords

thermal treatment
12
geopolymer gels
12
600 °c
12
increasing temperature
12
influence thermal
8
chemical structural
8
structural properties
8
properties geopolymer
8
900 °c
8
x-ray photoelectron
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!