Background: Implant rupture is a known complication in cosmetic breast surgery, but access and cost barriers hinder proper implant surveillance.
Objectives: In this study we aimed to validate high resolution ultrasound (HRUS) for diagnosing silicone implant rupture, and secondarily explore the predictors of implant rupture in a single-surgeon cohort.
Methods: A retrospective chart review identified patients who underwent HRUS of silicone breast implants that were placed by W.P.A. HRUS sensitivity and specificity and predictive values were calculated. Multivariable logistic regression assessed predictors of implant rupture. Kaplan-Meier methods estimated 10-year and 15-year implant survival.
Results: Among 254 patients (508 implants) included, 52 patients (104 implants) underwent operative exploration for various reasons; 20 implants had confirmed ruptures. Examining this operative cohort, HRUS had excellent positive and negative predictive value, respectively, 100% (95% CI 83.1%-100%) and 97.6% (95% CI 91.6-99.3%); the sensitivity was 90.9% (95% CI 70.8-98.9%) and specificity was 100% (95% CI 95.6%-100%). The median age of the implant at the time of ultrasound was 119 months (10 years; interquartile range 79-152 months). After multivariable adjustment, only the implant age was a significant predictor of implant rupture (P = .04). Across the entire cohort, Kaplan-Meier methods estimated 10-year and 15-year implant survival rates of 0.98 (95% CI 0.96-0.99) and 0.80 (95% CI 0.71-0.87), respectively. Subgroup analysis showed 10-year and 15-year implant survival rates of 0.99 and 0.92, respectively, for surveillance-only HRUS patients.
Conclusions: Plastic surgeon-delivered office-based HRUS surveillance is a highly sensitive and specific method for assessing silicone breast implant integrity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/asj/sjae165 | DOI Listing |
Eur Heart J Case Rep
January 2025
Department of Cardiology, Christian Medical College, New Arcot Road, Vellore 632517, India.
Background: Granulomatosis with polyangiitis (GPA) is an autoimmune multisystem disorder characterized by small vessel vasculitis with granulomatous inflammation. In this report, we describe a unique case of GPA who presented with complete heart block (CHB) and developed complications due to intracranial large vessel involvement.
Case Summary: A 47-year-old gentleman presented with CHB with a background history of arthralgia and blood-tinged nasal discharge.
J Craniofac Surg
October 2024
Department of Auricular Reconstruction, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shijingshan, Beijing, China.
Objective: For full expansion of ear reconstruction, the stability of a cartilage framework is very important. However, most techniques for framework fabrication focus on three-dimensional structure and adequate projection. Few studies are available on improving the stability of the reconstructed framework.
View Article and Find Full Text PDFBiomaterials
December 2024
Institut de Science des Matériaux de Mulhouse (IS2M), UMR 7361 CNRS/, Université de Haute Alsace (UHA), 15 rue Jean Starcky, 68057, Mulhouse Cedex, France. Electronic address:
Silicone-based breast implants are commonly used, but there are concerns about their long-term safety. While implantation results in the formation of a periprosthetic tissue that isolates the implant from the rest of the host body, silicone can leak and reach surrounding tissues. We combined histological analysis and gene expression profiling (RNA sequencing) of samples from human patients with silicone breast implants with different fillers (silicone or serum), surface topographies and/or shell rupture, and performed systematic cross-comparisons.
View Article and Find Full Text PDFFront Bioeng Biotechnol
December 2024
Orthopaedic Stem Cell Research Laboratory, Cedars-Sinai Medical Center, Los Angeles, CA, United States.
Introduction: Tendon injuries represent an ongoing challenge in clinical practice due to poor regenerative capacity, structure, and biomechanical function recovery of ruptured tendons. This study is focused on the assessment of a novel strategy to repair ruptured Achilles tendons in a Nude rat model using stem cell-seeded biomaterial.
Methods: Specifically, we have used induced pluripotent stem cell (iPSC)-derived mesenchymal stem cells (iMSCs) overexpressing the early tendon marker Scleraxis (SCX, iMSC, iTenocytes) in combination with an elastic collagen scaffold.
Proc (Bayl Univ Med Cent)
October 2024
Department of Gastroenterology and Hepatology, The University of Florida College of Medicine - Jacksonville, Jacksonville, Florida, USA.
Background: Endoscopic bariatric interventions are viable alternatives to traditional weight loss surgeries for patients with a body mass index between 30 and 40 kg/m. While studies have explored the impact of intragastric balloons on obesity and weight reduction, comprehensive data on real-world device-related complications and failures are limited. This study aimed to investigate mechanical failures leading to patient adverse events reported to the US Food and Drug Administration.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!