Purpose: We developed a novel guider-assisted osteotomy (GAO) procedure to improve the safety of open wedge high tibial osteotomy (OWHTO) and aimed to compare its efficacy and complications with the conventional pendulum-saw osteotomy (PSO).

Methods: This is a retrospective cohort study of patients undergoing either GAO or PSO procedure in the OWHTO to treat varus knee osteoarthritis, who had a minimum of 2 years of follow-up. Patients were propensity score matched (PSM) in a 1:1 ratio based on demographic and clinical data with a caliper width of 0.02. The outcomes assessed involved the hospital for special surgery (HSS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, and the Intraoperative and postoperative complications.

Results: 199 patients were included in each group after PSM. The mean duration of follow-up was 38.3 ± 8.9 months. The GAO group had a shorter operation duration (104.5 ± 35.7 vs. 112.1 ± 36.0 min, p = 0.027) and fewer times of intraoperative fluoroscopy (4.2 ± 1.4 vs. 6.0 ± 1.4, p < 0.001). At the last follow-up, clinical scores for knee achieved significant improvements in both GAO and PSO groups: HSS (67.5 ± 10.5 vs. 90.2 ± 7.0, p < 0.001; 69.4 ± 8.2 vs. 91.7 ± 6.8, p < 0.001) and WOMAC (65.7 ± 11.6 vs. 25.2 ± 10.4, p < 0.001; 63.3 ± 12.2 vs. 23.8 ± 9.5, p < 0.001). However, no significant difference was observed between groups for any measures (p > 0.05). In addition, the intraoperative complications (0.5% vs. 3.5%, p = 0.068) and the postoperative bone delayed union and nonunion (1.0% vs. 4.5%, p = 0.032) were marginally or significantly reduced in the GAO versus PSO group.

Conclusion: GAO demonstrates improvements in intraoperative radiation exposure and complications, with comparable short-term efficacy to PSO, and could be considered a viable alternative in clinical practice.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11271211PMC
http://dx.doi.org/10.1186/s13018-024-04909-3DOI Listing

Publication Analysis

Top Keywords

guider-assisted osteotomy
8
conventional pendulum-saw
8
pendulum-saw osteotomy
8
open wedge
8
wedge high
8
high tibial
8
tibial osteotomy
8
cohort study
8
osteotomy
6
clinical outcomes
4

Similar Publications

Purpose: We developed a novel guider-assisted osteotomy (GAO) procedure to improve the safety of open wedge high tibial osteotomy (OWHTO) and aimed to compare its efficacy and complications with the conventional pendulum-saw osteotomy (PSO).

Methods: This is a retrospective cohort study of patients undergoing either GAO or PSO procedure in the OWHTO to treat varus knee osteoarthritis, who had a minimum of 2 years of follow-up. Patients were propensity score matched (PSM) in a 1:1 ratio based on demographic and clinical data with a caliper width of 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!