Study Design: A systematic review and meta-analysis.

Objective: This study aims to compare pedicle screw accuracy, clinical outcomes, and complications between navigated and conventional techniques.

Summary Of Background Data: In the last decades, intraoperative navigation has been introduced in spinal surgery to prevent risks and complications.

Materials And Methods: The search was executed on Cochrane Central Library, PubMed, and Scopus on April 30, 2023. Randomized controlled trials, prospective and retrospective studies that compared pedicle screw accuracy in the thoracic-lumbar-sacral segments, blood loss, operative time, hospital stay, intraoperative and postoperative revision of screws, neurological and systemic complications, Visual Analogue Scale (VAS), and Oswestry Disability Index (ODI) between navigated and freehand or fluoroscopy-assisted techniques were included in this study. The meta-analysis was performed using Review Manager software. Clinical outcomes were assessed as continuous outcomes with mean difference, while pedicle screw accuracy and complications were assessed as dichotomous outcomes with odds ratio, all with 95% CIs. The statistical significance of the results was fixed at P <0.05.

Results: This meta-analysis included 30 studies for a total of 17,911 patients and 24,600 pedicle screws. Statistically significant results in favor of the navigated technique were observed for the accuracy of pedicle screws ( P =0.0001), hospital stay ( P =0.0002), blood loss ( P <0.0001), postoperative revision of pedicle screws ( P <0.00001), and systemic complications ( P =0.0008). In particular, the positioning of the screws was clinically acceptable in 96.2% of the navigated group and 94.2% with traditional techniques. No significant differences were found in VAS, ODI, and operative time between the two groups.

Conclusion: Navigated pedicle screw fixation has been demonstrated to be a safe and effective technique with high improvement in clinical outcomes and accuracy in patients undergoing spinal fusion compared with conventional techniques.

Level Of Evidence: Level III.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11386964PMC
http://dx.doi.org/10.1097/BRS.0000000000005105DOI Listing

Publication Analysis

Top Keywords

pedicle screw
16
clinical outcomes
12
screw accuracy
12
systematic review
8
outcomes
5
higher accuracy
4
accuracy better
4
better clinical
4
outcomes navigated
4
navigated thoraco-lumbar
4

Similar Publications

Objectives: The advent of O-arm navigation optimized the oblique lumbar interbody fusion (OLIF) procedure, allowing the operator to simultaneously perform OLIF and percutaneous posterior pedicle screw implantation without patient position change, thus improving the fluency and accuracy of the OLIF procedure (called as OLIF360). Nevertheless, a consensus regarding its suitability for patients with severe spinal stenosis remains elusive. This study aims to investigate the clinical efficacy of OLIF360 and its imaging changes in severe lumbar spinal stenosis cases.

View Article and Find Full Text PDF

Background: Tropical Candida spondylitis is an uncommon cause of lower back pain in patients, especially in non-tropical areas or in patients not at risk of immunocompromise.

Case Presentation: A 65-year-old woman presented with a six-month history of poorly managed low back pain, now accompanied by numbness and pain in both lower extremities. Her medical history was significant for tertiary hypertension.

View Article and Find Full Text PDF

This descriptive longitudinal study aims to assess the risk factors for severe thoracic and lumbar vertebral compression fractures before and after surgery, contributing to preventive knowledge enhancement in communities and effective treatment management. The study involved 34 patients diagnosed with thoracic and lumbar vertebral compression fractures requiring surgery with bio-cement-augmented pedicle screws between June 2021 and June 2022. Postoperative complications, notably adjacent segment injury, were monitored, and patients received osteoporosis management post-surgery.

View Article and Find Full Text PDF

Cement-augmented pedicle screw instrumentation is a widely accepted method for managing osteoporotic fractures, but it carries inherent risks, particularly related to cement leakage and embolism. This study aimed to analyze a clinical case of complications following cement fixation and provide a detailed review of relevant literature. A 70-year-old patient underwent transpedicular screw instrumentation from L2-L4 with polymethyl methacrylate augmentation, which resulted in cement leakage into the spinal canal and subsequent pulmonary embolism.

View Article and Find Full Text PDF

Osteoporotic vertebral fractures (OVFs) in elderly patients pose challenges due to bone destruction and surgical risks. This case report describes a minimally invasive approach using calcium phosphate cement (CPC) vertebroplasty and short fusion with cement augmentation of pedicle screws (CAPS) in a 91-year-old woman with severe OVF. The patient underwent CPC vertebroplasty at L1 and CAPS fixation at T12-L2, followed by osteoporosis medication.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!