A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Imaging light fluence in blood vessels by combining photoacoustic fluctuation imaging and ultrasound power Doppler. | LitMetric

Imaging light fluence in blood vessels by combining photoacoustic fluctuation imaging and ultrasound power Doppler.

Phys Med Biol

University Grenoble Alpes, CNRS, LIPhy, 140 rue de la Physique, CS 40700, 38058 Grenoble CEDEX 9, France.

Published: August 2024

Numerous optical biomedical imaging or therapeutic modalities suffer from unknown light fluence distribution at depths. Photoacoustic (PA) imaging, which enables imaging blood vessels at the acoustic resolution, probes the product between the fluence and effective optical absorption that depends on the size or density of blood vessels. In the case of unresolved vessels, fluence and absorption can not be decoupled using PA imaging alone without the use of inverse problems. Thus, we propose combining two modalities that are sensitive to blood vessels to directly image fluence maps within vascularized areas, including in unresolved vessels.To achieve fluence imaging, the combination of photoacoustic fluctuation (PAFI) and Ultrasound Power Doppler (UPD) images is considered. After exposing a new theoretical expression of the UPD image, we establish a fluence imaging method giving quantitative fluence in blood vessels. Fluence imaging involves resolution compensation with a PSF filter that is compared to alternative simpler corrections.This method universally applies to arbitrary hematocrit and multi-scale vessel imaging. Using a spherical sparse array, we demonstrate 3D fluence imaging within blood vessels in simulation and experiments which is not possible with PAFI alone.Overall, we show that combining PAFI and UPD has the potential for real-time light dosimetry or could enhance quantitative inverse problems in PA imaging.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/ad672eDOI Listing

Publication Analysis

Top Keywords

blood vessels
24
fluence imaging
16
imaging
12
fluence
10
light fluence
8
fluence blood
8
photoacoustic fluctuation
8
ultrasound power
8
power doppler
8
imaging blood
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!