A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Impact of reducing iodinated intravenous contrast volume in brain CT on image diagnostic quality. | LitMetric

Purpose: To investigate whether reducing the volume of intravenous iodinated contrast material injected during brain computed tomography (CT) provides reliable and accurate imaging without compromising diagnostic accuracy.

Methods: This prospective study enrolled patients undergoing enhanced brain CT at a single tertiary hospital. Subjects who agreed to participate received a reduced dose of 60 ml contrast. The images were compared to an age and gender-matched control group who received the conventional 80 cc dose. Neuroradiologists assessed image quality and interpretation using a 5-point Likert scale with six specific domains. Based on ICC, inter-rater reliability was high at 0.873. Multiple linear regression predicted overall diagnostic accuracy based on contrast dose, age, and gender. Visual Grading Characteristics (VGC) analysis was also performed to quantify regional brain enhancement differences between the two contrast groups.

Results: The study included 47 patients in the 60 cc group and 55 in the 80 cc control group. The results showed the 80 cc group had significantly higher enhancement ratings compared to 60 cc for all six structures assessed. The differences between groups ranged from -0.241 to -0.433 (p < 0.001) on the 5-point scale.The VGC analysis confirmed significantly greater brain parenchymal enhancement in the 80 cc group compared to the 60 cc group.

Conclusion: The findings indicate that reducing the intravenous iodinated contrast material volume during brain CT from 80 cc to 60 cc leads to a statistically significant reduction in image quality and diagnostic accuracy. Further research with larger cohorts is needed to confirm these findings and assess the clinical impact of these differences.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejrad.2024.111635DOI Listing

Publication Analysis

Top Keywords

control group
8
group 80 cc
8
contrast
5
impact reducing
4
reducing iodinated
4
iodinated intravenous
4
intravenous contrast
4
contrast volume
4
brain
4
volume brain
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!