Objective: To compare the test-retest reliabilities and minimal detectable change (MDC) of the Short Portable Mental State Questionnaire (SPMSQ) and the Montreal Cognitive Assessment (MoCA) in patients with stroke.
Methods: 63 patients were recruited from 1 medical center. The SPMSQ and MoCA were administered twice, 2 weeks apart.
Results: Both measures showed high intraclass correlation coefficients (SPMSQ: 0.87; MoCA: 0.89) and acceptable MDC%s (SPMSQ: 14.8%; MoCA: 19.6%). A small correlation ( = 0.30) was found between the absolute difference and average in each pair of assessments in the SPMSQ, which was close to the criterion of heteroscedasticity. A small practice effect was observed in the MoCA (Cohen's = 0.30).
Conclusion: The SPMSQ demonstrated smaller random measurement error and an absence of practice effect. When comparing the psychometric properties of the SPMSQ and MoCA as outcome measures for assessing cognitive function in patients with stroke, the SPMSQ appears to be a more suitable choice than the MoCA.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/08919887241266793 | DOI Listing |
Sensors (Basel)
January 2025
School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu 611731, China.
Lithium-ion batteries represent a significant component of the field of energy storage, with a diverse range of applications in consumer electronics, portable devices, and numerous other fields. In view of the growing concerns about the safety of batteries, it is of the utmost importance to develop a sensor that is capable of accurately monitoring the internal temperature of lithium-ion batteries. External sensors are subject to the necessity for additional space and ancillary equipment.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Sensor Science Division, National Institute of Standards and Technology, Gaithersburg, MD 20878, USA.
Terrestrial laser scanners (TLS) are portable dimensional measurement instruments used to obtain 3D point clouds of objects in a scene. While TLSs do not require the use of cooperative targets, they are sometimes placed in a scene to fuse or compare data from different instruments or data from the same instrument but from different positions. A contrast target is an example of such a target; it consists of alternating black/white squares that can be printed using a laser printer.
View Article and Find Full Text PDFInsects
January 2025
Council for Agricultural Research and Economics, Research Centre for Engineering and Agro-Food Processing, Via della Pascolare 16, 00015 Monterotondo, Italy.
Beekeeping is a crucial agricultural practice that significantly enhances environmental health and food production through effective pollination by honey bees. However, honey bees face numerous threats, including exotic parasites, large-scale transportation, and common agricultural practices that may increase the risk of parasite and pathogen transmission. A major threat is the mite, which feeds on honey bee fat bodies and transmits viruses, leading to significant colony losses.
View Article and Find Full Text PDFMicromachines (Basel)
December 2024
College of Information Science and Electronic Engineering, Zhejiang University, Hangzhou 310027, China.
The triboelectric nanogenerator (TENG) has emerged as a promising technology for efficiently converting ambient mechanical energy into electrical energy. Among various designs, the disk-based rotational TENG has demonstrated significant potential, as it can continuously harvest energy in a sliding mode via a grating mechanism. However, horizontal mechanical energy is more common than rotational energy in many practical applications.
View Article and Find Full Text PDFMicrobiol Spectr
January 2025
Ifremer, ASIM, La Tremblade, France.
Since the 1990s, the Pacific oyster has faced significant mortality, which has been associated with the detection of the Ostreid Herpesvirus type 1 (OsHV-1). Due to the complex genomic architecture and the presence of multiple genomic isomers, short-read sequencing using Illumina method struggles to accurately assemble tandem and repeat regions and to identify and characterize large structural variations in the OsHV-1 genome. Third-generation sequencing technologies, as long-read real-time nanopore sequencing from Oxford Nanopore Technologies (ONT), offer new possibilities for OsHV-1 whole-genome analysis.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!