Objective: This study aimed to validate the effectiveness, accuracy, and feasibility of the cut-plane method for measuring the side branch (SB) ostium area in three-dimensional optical coherence tomography (3D-OCT) pullbacks performed in the main branch (MB).
Methods: A total of 109 sets of OCT pullbacks from the MB and SB of coronary artery bifurcation lesions were analyzed using Vivolight OCT software. Measurements of the SB ostium area from the MB and SB pullbacks were analyzed. Measurements of the SB ostium area from the actual SB pullback were used as a reference. 3D cut-plane analysis was used to estimate the correlations and mean errors with the reference measurements.
Results: Thirty-four sets of OCT images from the C7XR system and 75 sets from the Cornaris system were analyzed using Vivolight software. There was a strong correlation between the reference measurements of the SB ostium area and the measurements obtained through 3D cut-plane analysis in the overall dataset (r = 0.925). This correlation was observed consistently with both the C7XR system (r = 0.955) and Cornaris system (r = 0.900). Similar results were found in subset analyses of true and nontrue bifurcations (r = 0.936; r = 0.898, respectively) and in left main (LM) or non-LM bifurcation subsets (r = 0.932; r = 0.873, respectively).
Conclusions: There were strong correlations between measurements of the SB ostium area by 3D-OCT and the reference measurements, and thus may be a reliable and accurate alternative to direct OCT pullback examinations of the SB.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11261366 | PMC |
http://dx.doi.org/10.6515/ACS.202407_40(4).20240504A | DOI Listing |
Pulmonary vein anatomical variations are frequently observed in atrial fibrillation patients undergoing catheter ablation. However, when it comes to patients with atrial fibrillation and bilateral common ostium in the inferior pulmonary veins, using a bilateral circumferential pulmonary vein isolation approach during catheter ablation heightens the risk of esophageal injury. At present, there is no established standard catheter ablation strategy for such cases.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
December 2024
Department of Cardiology, Aarhus University Hospital, Aarhus, Denmark.
Background: Extubation of the coronary guiding catheter may affect flow and pressure measurements in the coronary vessel during invasive coronary angiography (ICA).
Aim: This study aims to investigate the impact of guiding catheter extubation on fractional flow reserve (FFR), coronary flow reserve (CFR), and the index of microcirculatory resistance (IMR).
Methods: This predefined subgroup analysis of the Dan-NICAD 2 study included patients with chronic coronary syndrome referred to ICA based on a coronary computed tomography angiography.
Eur Heart J Case Rep
December 2024
Department of Cardiology, Sendai Kousei Hospital, 1-20, Tsutsumidori Amamiya-cho, Aoba-ku, Sendai, Miyagi 981-0914, Japan.
Background: Balloon-assisted bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction (BA-BASILICA) enables valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) in patients at risk of coronary artery obstruction. However, its efficacy in patients with severely calcified leaflets remains unclear.
Case Summary: We report a 78-year-old woman with a deteriorated 21 mm Carpentier-Edwards PERIMOUNT Magna valve.
The Choke Mountain in northern Ethiopia is remarkable due to its highly diverse Trechini fauna. Based on numerous specimens recently collected in the high montane and afroalpine zones along different slopes of Mt. Choke we revise the species related to Trechus niloticus (Quéinnec & Ollivier) and T.
View Article and Find Full Text PDFEuropace
November 2024
Faculty of Medicine and Surgery, Vita-Salute San Raffaele University, Via Olgettina 58, 20097 Milan, Italy.
Aims: The third-generation laser balloon (LB3) is an established ablation device for pulmonary vein isolation (PVI) that allows direct visualization of the anatomical target. Equipped with an automatic circumferential laser delivery modality, it aims at continuous circumferential PVI, improving both acute and clinical outcomes. We sought to evaluate the clinical efficacy of LB3 ablation using an anatomical-based approach without verifying electrical isolation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!