A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Esophageal impedance planimetry during per-oral endoscopic myotomy guides myotomy extent. | LitMetric

AI Article Synopsis

  • POEM is the main treatment for achalasia, and FLIP technology aids in real-time assessment of the lower esophageal sphincter to improve surgical outcomes.
  • The study analyzed data from 14 patients who underwent POEM using FLIP from June 2020 to January 2023, noting significant improvements in key metrics like distensibility index and symptom scores after the procedure.
  • The findings suggest FLIP is valuable for monitoring surgery effectiveness, as it can indicate when additional myotomy is needed and identify patients who may require further treatment for recurring symptoms.

Article Abstract

Introduction: Peroral endoscopic myotomy (POEM) is the standard treatment for achalasia. Functional luminal imaging probe (FLIP) technology enables objective measurement of lower esophageal sphincter (LES) geometry, with literature linking specific values to improved post-POEM outcomes. Our study assesses FLIP's intraoperative use in evaluating myotomy extent in real-time.

Methods: Retrospective data from all patients undergoing POEM with intraoperative FLIP measurements were extracted from June 2020 to January 2023. The primary endpoint was intraoperative FLIP measurements, management changes, and symptom improvement (Eckardt score).

Results: Fourteen patients (age 56 ± 14 years, BMI 28 ± 7 kg/m) were identified. Most patients were female (64%). Predominantly, patients presented with type II achalasia (50%). FLIP measurements were taken before and after myotomy, demonstrating increases in mean distensibility index (DI) 1.6 ± 1. 4 to 5.4 ± 2.1 mm/mmHg (p < 0.05) and mean diameter (Dmin) 6 ± 1.8 to 10.9 ± 2.3 mm (p < 0.05) at 50 ml balloon fill. Additional myotomy was performed in one patient when an inadequate increase in FLIP values were noted. Mean operative time was 98 ± 28 min, and there were no intraoperative complications. At the 30-day follow-up, median Eckardt score decreased from mean a preoperative score of 7 ± 2 to a post-operative mean of 2 ± 3, with 10 patients (78%) having a score ≤ 2. In total, four patients experienced symptom recurrence, with repeat FLIP values revealing a significant decrease in DI from 7 ± 2.2 post-POEM to 2.5 ± 1.5 at recurrence. FLIP technology identified LES pathology in 3 out of 4 (75%) patients, facilitating referral to LES-directed therapy.

Conclusion: Our study adds to the literature supporting the use of FLIP technology during the POEM procedure, with most patients achieving ideal values after a standard-length myotomy. This suggests the potential benefits of shorter myotomies guided by FLIP to achieve comparable outcomes and reduce postoperative GERD risk. Collaborative standardization of study designs and outcome measures is crucial for facilitating prospective trials and cross-setting outcome comparisons.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11362179PMC
http://dx.doi.org/10.1007/s00464-024-11067-4DOI Listing

Publication Analysis

Top Keywords

flip measurements
12
endoscopic myotomy
8
myotomy extent
8
intraoperative flip
8
myotomy
5
esophageal impedance
4
impedance planimetry
4
planimetry per-oral
4
per-oral endoscopic
4
myotomy guides
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!