Introduction: Various computer-assisted surgical systems claim to improve the accuracy of cup placement in total hip arthroplasties after assessing spinopelvic mobility to prevent prosthetic impingement. However, no study has yet analyzed the extent of the patient-specific cup anteversion safe zones.

Hypothesis: We hypothesized that most patients have a safe zone >10 °, except those with abnormal spinopelvic mobility, who have a much narrower safe zone.

Materials And Methods: We simulated the risks of prosthetic impingement using the planned cup anteversion. The consecutive cohort included 341 patients who underwent total hip arthroplasty. Our primary endpoint was the patient-specific impingement-free zone for cup anteversion, which was then divided into four subgroups: 0 °, 1 ° to 5 °, 6 ° to 10 °, and >10 °. This data was then secondarily analyzed for abnormal spinopelvic mobility (the difference in the spinopelvic tilt [ΔSPT] from a standing to a flexed seated position >20 °).

Results: The mean anteversion safe zone was 22.8 ° with 82.4% (281/341) of patients with a zone strictly >10 °. The mean safe zone was 8.9 ° (+/- 9 °) in patients with an ΔSPT ≥20 ° (18.2%), with 37.1% of these patients having a zone of 0 °, 16.13% a zone between 1 ° and 5 °, 8.06% a zone between 6 ° and 10 ° and 38.71% a zone >10 °. The mean safe zone was 25.9 ° (+/- 9 °) in patients with an ΔSPT <20 ° (81.8%), and the proportion of cases in each zone was 2.51%, 1.08%, 4.3%, and 92.11%, respectively (p < 0.001).

Conclusion: The safe zone for anteversion appears to be fairly wide in most patients. However, identifying patients at risk of abnormal spinopelvic mobility seems necessary to identify the two-thirds of patients with a narrow safe zone.

Level Of Evidence: IV; retrospective study.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.otsr.2024.103940DOI Listing

Publication Analysis

Top Keywords

safe zone
20
cup anteversion
16
anteversion safe
12
spinopelvic mobility
12
zone
11
total hip
8
prosthetic impingement
8
zone >10 °
8
abnormal spinopelvic
8
1 ° 5 °
8

Similar Publications

: Instability is a major reason for revision after total hip arthroplasty (THA), and acetabular cup placement in the "traditional" safe zone does not protect against dislocations. Spinopelvic mobility may play a role in impingement and dislocation after THA. Personalized acetabular cup placement that incorporates spinopelvic mobility is currently lacking in the literature.

View Article and Find Full Text PDF

Background: Is "eyeballing" enough to determine cup malposition on anteroposterior (AP) pelvis radiographs before revision total hip arthroplasty (rTHA) for instability? We aimed to determine the following: (1) the reliability of eyeballing cup inclination/anteversion on AP pelvis radiographs vs geometrical measurements and (2) whether visual assessments are affected by surgeon experience.

Materials And Methods: Fifteen de-identified standing AP pelvis radiographs obtained before rTHA for instability were evaluated by one orthopedic surgeon who measured inclination/anteversion of the cups (n=15) using a new simplified method based on basic geometry. Subsequently, 4 orthopedic surgeons and 4 fellows (postgraduate year 6) assessed inclination/anteversion by eyeballing.

View Article and Find Full Text PDF

Simulation training provides health professions learners access to training not readily available to them and in a manner that does not harm patients. Simulation also supports learners to develop dispositions and professional communication and reflect on their biases. This study examines how learners, clinical education faculty, and simulation professionals reflect on diversity and antiracism in simulation and contextualize these reflections with their lived experience.

View Article and Find Full Text PDF

Objective: To investigate the positioning of deep epigastric vessels in obese patients to determine the need to redefine laparoscopic port placement 'safe zones' based on body habitus.

Design: Retrospective case series.

Setting: University-affiliated 500-bed hospital.

View Article and Find Full Text PDF

Findings and Recommendations From a Series of Workshops on Hospital Emergency Responses to an Improvised Nuclear Device Detonation.

Health Secur

December 2024

Jenna Mandel-Ricci, MPA, MPH, is Chief of Staff; both at the New York City Department of Health and Mental Hygiene, Long Island City, NY.

The New York City Department of Health and Mental Hygiene and the Greater New York Hospital Association held 3 workshops and 2 follow-up meetings with hospital emergency managers and colleagues to determine hospitals' response actions to a scenario of a 10-kiloton improvised nuclear device detonation. The scenario incorporated 3 zones of damage (moderate, light, and beyond damage zones) and covered the period of 0 to 72 hours postdetonation divided into 3 24-hour operational periods. The Joint Commission's critical emergency areas were used to determine the objectives and response actions that would be initiated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!