A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Study of a method for theoretical calculation of the efficiency of a LaBr(Ce) for detecting gamma-rays from point sources. | LitMetric

Study of a method for theoretical calculation of the efficiency of a LaBr(Ce) for detecting gamma-rays from point sources.

Appl Radiat Isot

Institution of NBC Defence, Beijing, 102205, China. Electronic address:

Published: October 2024

A theoretical model for calculating the full-energy peak efficiency of scintillator detector is proposed in this paper. The effective penetration distance of gamma-rays in Ø3.81cm × 3.81 cm LaBr(Ce) crystal, aluminum shell and MgO reflector is analyzed. The calculation model for point source detection efficiency is derived, and the attenuation of gamma-rays in the detector shell is computed by theoretical calculation method. This method is used to calculate the efficiency of LaBr(Ce) with a size of Ø3.81 × 3.81 cm for detecting gamma-rays from point sources of Cs and Co located in different positions. Compared with experimental data and Monte Carlo (MC) simulation results, the maximum relative deviation is less than 5%. The attenuation of gamma-rays with an energy of 60 keV is more than 50%. The fitted efficiency calibration curve in the energy range of 60 keV-1500 keV is in good agreement with the simulation results. The results show that this method is suitable for calculating the efficiency of the LaBr(Ce) detector using point sources, especially for analyzing low-energy gamma ray sources. By taking into account the attenuation of the gamma-rays by the detector shell, the measurement accuracy can be effectively improved. The proposed method can be extended for the efficiency calibration of scintillator detectors with various shapes and provides a new approach for 'source-less' efficiency calibration of detectors.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apradiso.2024.111446DOI Listing

Publication Analysis

Top Keywords

efficiency labrce
12
point sources
12
attenuation gamma-rays
12
efficiency calibration
12
theoretical calculation
8
efficiency
8
detecting gamma-rays
8
gamma-rays point
8
gamma-rays detector
8
detector shell
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!