A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Prognostic value of serum albumin in heart failure patients with cardiac resynchronization therapy. | LitMetric

AI Article Synopsis

  • The study investigates the link between serum albumin levels and long-term mortality in heart failure patients with cardiac resynchronization therapy defibrillators (CRT-D).
  • A total of 477 heart failure patients with CRT-D were analyzed, divided into three groups based on their albumin levels.
  • Results showed that low albumin levels significantly correlated with higher rates of all-cause mortality and both appropriate and inappropriate shocks in patients with CRT-D.

Article Abstract

There is a lack of data about the association between admission serum albumin levels and long-term mortality in heart failure (HF) patients with cardiac resynchronization therapy defibrillators (CRT-D). We aim to investigate this connection in HF patients with CRT-D. The study population consisted of 477 HF patients with CRT-D. The cohort was divided into three groups according to albumin values, and the relationship between these groups and long-term mortality were evaluated. Long-term all-cause mortality (HR: 3.32, 95% CI: 2.12-6.84), appropriate (HR: 4.44, 95% CI: 2.44-8.06) and inappropriate (HR: 2.95, 95% CI: 1.88-6.02) shocks were higher in the low albumin group. Low albumin levels are associated with the long-term mortality and appropriate shock treatment in HF patients with CRT-D.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11285214PMC
http://dx.doi.org/10.1080/17520363.2024.2347200DOI Listing

Publication Analysis

Top Keywords

long-term mortality
12
patients crt-d
12
serum albumin
8
heart failure
8
failure patients
8
patients cardiac
8
cardiac resynchronization
8
resynchronization therapy
8
albumin levels
8
low albumin
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!