Clinical outcomes of conjunctivochalasis treatment with a new ophthalmic radiofrequency device.

BMC Ophthalmol

Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.

Published: July 2024

Purpose: To investigate the safety and efficacy of a new micro-controlled radiofrequency device for treatment of conjunctivochalasis (Cch).

Methods: Data of 127 patients (230 eyes) who underwent ophthalmic radiofrequency treatment for Cch from January 2020 to June 2023 were analyzed retrospectively. Cch coagulation was performed with a radiofrequency electrode tip (OcuRF®, Ilooda, Korea) and a high-frequency radio-wave electric unit (0.6 ~ 0.8 watts, 2 MHz, Acutron™, Ilooda, Korea). Pre- and postoperative Cch grading, slit-lamp photography, tear film break-up time (TBUT), and bulbar conjunctival hyperemia using Keratograph 5 M (Oculus, Wetzlar, Germany) were evaluated. Cch grade 0 or 1 after surgery was regarded as 'success'. Complications, recurrence, and additional treatment rates were analyzed.

Results: In 227 (98.7%) eyes, the radiofrequency treatment led to marked improvement of Cch, with 224 (97.4%) eyes achieving grade 0 or 1 at 2 months postoperatively. Eight eyes (3.5%) received additional treatment. TBUT improved from 3.17 ± 0.82 s to 5.28 ± 1.10 s after surgery (P < 0.001). The total bulbar conjunctival hyperemia value showed an improvement from 1.7 ± 0.6 to 1.4 ± 0.6 postoperatively (P < 0.05). No serious complications were observed.

Conclusion: The novel ophthalmic radiofrequency device led to a marked improvement of Cch with no serious adverse events during the entire follow-up period. Our results suggest that the radiofrequency device presents a safe and efficacious treatment option for Cch.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11265150PMC
http://dx.doi.org/10.1186/s12886-024-03499-2DOI Listing

Publication Analysis

Top Keywords

ophthalmic radiofrequency
8
radiofrequency device
8
radiofrequency treatment
8
ilooda korea
8
additional treatment
8
treatment
6
radiofrequency
5
cch
5
clinical outcomes
4
outcomes conjunctivochalasis
4

Similar Publications

To determine in which cases ablative radiofrequency microplasma is preferred for the treatment of lateral dermatochalasis over a surgical approach as well as discussing each method's benefits and limitations. Twenty-one patients underwent 3 interventions of plasma exeresis. Photographic and RCM images were acquired at baseline and 4 weeks after final plasma exeresis.

View Article and Find Full Text PDF

Objective: To present a case series analysis of surgical treatment of patients with secondary trigeminal neuralgia.

Material And Methods: The treatment of 8 patients with secondary trigeminal neuralgia who underwent surgery since 2021 was analyzed. All records, neuroimaging archive, and follow-up observations were reviewed.

View Article and Find Full Text PDF
Article Synopsis
  • This study aimed to compare the effectiveness and safety of ultrasound-guided versus computed tomography-guided pulsed radiofrequency treatments for ophthalmic branch postherpetic neuralgia in 84 patients.
  • Results revealed that the ultrasound-guided method had a significantly shorter puncture time and lower rates of certain adverse events compared to the computed tomography-guided method.
  • While both techniques effectively reduced pain scores after treatment, there was no significant difference in pain relief or overall treatment effectiveness between the two groups after 12 weeks.
View Article and Find Full Text PDF

The most common source of Radiofrequency Electromagnetic Field (RF-EMF) exposures during sleep includes digital devices, yet there are no studies investigating the impact of multi-night exposure to electromagnetic fields emitted from a baby monitor on sleep under real-world conditions in healthy adults. Given the rise in the number of people reporting to be sensitive to manmade electromagnetic fields, the ubiquitous use of Wi-Fi enabled digital devices and the lack of real-world data, we investigated the effect of 2.45 GHz radiofrequency exposure during sleep on subjective sleep quality, and objective sleep measures, heart rate variability and actigraphy in healthy adults.

View Article and Find Full Text PDF
Article Synopsis
  • The study focused on the safe use of radiofrequency ablation for thyroid nodules while protecting the recurrent laryngeal nerve from thermal damage using a porcine animal model.
  • Twelve piglets were tested at various radiofrequency power levels, with monitoring of real-time signal changes to assess safety distances and cooling durations related to the nerve.
  • Results showed that at set power levels, there were significant signal reductions near the nerve, with no recovery in a 20-minute window, indicating careful management is necessary during procedures to prevent nerve injury.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!