V-flow is a dynamic ultrasound technique that visualizes perfusion patterns by displaying dynamic arrows that change in response to the flow of erythrocytes. Furthermore, it provides quantitative values for the maximum and mean velocity of blood flow as well as a percentage value for turbulence. The aim was to enhance the preoperative diagnostic accuracy of thyroid lesions by combining V-flow with established ultrasound modes.B-mode, CCDS, elastography, CEUS, and V-flow were performed on 101 patients. After the ultrasound examination, every nodule was confirmed as benign or malignant via histopathology. The Kruskal-Wallis test, ROC curve, and binary logistic regression were used for the statistical analysis.93 benign regressive thyroid nodules and 8 carcinomas were included in this study. The average mean velocity value for benign lesions was measured at 19.5 cm/s and at 10.7 cm/s for malignant lesions (p = 0.039). The average turbulence percentage was 26.1% for benign nodules and 46.7% for carcinomas (p = 0.016). Carcinomas exhibited a slower and more turbulent perfusion pattern compared to benign tumors. A V-flow-centered system achieves a sensitivity of 100.0% and a specificity of 84.9% in predicting malignancy. This system could have reduced the number of unnecessary thyroid surgeries for benign lesions in our patient group by 70%.The capillary perfusion of thyroid nodules represents a significant indicator of its status. By analyzing the velocity and turbulence level of microvascular blood flow, V-flow offers promising prospects for accurately distinguishing between benign and malignant thyroid lesions. When integrated into a comprehensive multimodal sonographic imaging approach, V-flow further enhances diagnostic accuracy. · V-flow allows for qualitative and quantitative analysis of microvascular perfusion. · Malignant tumors are associated with slower and more turbulent microvascular hemodynamics. · Combining V-flow with other ultrasound modes eases the diagnosis of thyroid carcinomas. · Brandenstein MK, Zhang L, Scharf G et al. The impact of V-flow on preoperative diagnosis of thyroid tumors: individually and as part of multimodal sonographic imaging. Fortschr Röntgenstr 2024; DOI 10.1055/a-2350-0107.

Download full-text PDF

Source
http://dx.doi.org/10.1055/a-2350-0107DOI Listing

Publication Analysis

Top Keywords

diagnosis thyroid
12
multimodal sonographic
12
sonographic imaging
12
impact v-flow
8
v-flow preoperative
8
preoperative diagnosis
8
thyroid
8
thyroid tumors
8
tumors individually
8
individually multimodal
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!