A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

National programme for the reliability of ionizing radiation measurements based on inter-laboratory comparisons (ILCs): ILC n°2 'radiopharmaceutical activities'. | LitMetric

A national Inter-Laboratory Comparisons (ILCs) programme was organized in Italy in 2022 by the Italian National Institute of Ionizing Radiation Metrology (INMRI), belonging to ENEA (Italian National Agency for New Technologies, Energy and Sustainable Economic Development), under the auspices of the Ministry of Enterprises and Made in Italy (Mimit ex MiSe). Within this ILCs programme, six inter-laboratory comparisons were organized, including the ILC-2 which focused on activity measurements carried out with radionuclide calibrators commonly used in the nuclear medicine departments of the participants. The focus was on three short-lived radionuclides - Tc, F, Lu - commonly employed in nuclear medicine for both diagnostic and therapeutic purposes. All presented results were compared with the reference values provided by ENEA-INMRI to ensure the traceability of measurements to the national primary activity standards. The observed deviation from the reference values of the measured activity were mainly within ± 10% (100% for F, 91.7% for Tc, 100% for Lu). The E statistical estimator was used to assess the participants' ability to estimate uncertainty in the provided activity values. The obtained values revealed that, in certain instances, the involved laboratories did not achieve the correct results for E (with failure rates of 22.7%, 16.7%, 12.5% for F, Tc, Lu, respectively), despite deviations from the reference values falling within the ± 10%. The aim of ILC-2 was to harmonize the activity measurements in the country within the field of nuclear medicine for the specific radionuclides studied and enhance the measurement capabilities of the participants.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apradiso.2024.111449DOI Listing

Publication Analysis

Top Keywords

inter-laboratory comparisons
12
nuclear medicine
12
reference values
12
ionizing radiation
8
comparisons ilcs
8
ilcs programme
8
italian national
8
activity measurements
8
national
5
activity
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!