AI Article Synopsis

  • This study compared the outcomes of two aortic valve replacement methods—sutureless aortic valve replacement (SUAVR) and transcatheter aortic valve implantation (TAVI)—in patients with small aortic annulus (SAA).
  • A total of 622 patients were analyzed, and after matching for key characteristics, 146 patients from each group were evaluated for all-cause death at 36 months and other complications.
  • Results indicated that the TAVI group had a higher rate of all-cause death (21% vs. 12.2%) and more major adverse cardiovascular and cerebrovascular events (32.6% vs. 18.1%), while both methods showed similar hemodynamic performances.

Article Abstract

Objective: This study aimed to compare hemodynamic performances and clinical outcomes of patients with small aortic annulus (SAA) who underwent aortic valve replacement by means of sutureless aortic valve replacement (SUAVR) or transcatheter aortic valve implantation (TAVI).

Methods: From 2015 to 2020, 622 consecutive patients with SAA underwent either SUAVR or TAVI. Through a 1:1 propensity score matching analysis, two homogeneous groups of 146 patients were formed. Primary endpoint: all cause-death at 36 months. Secondary endpoints: incidence of moderate to severe patient-prosthesis mismatch (PPM) and incidence of major adverse cardiovascular and cerebrovascular events (MACCEs).

Results: All-cause death at three years was higher in the TAVI group (SUAVR 12.2% vs. TAVI 21.0%, P=0.058). Perioperatively, comparable hemodynamic performances were recorded in terms of indexed effective orifice area (SUAVR 1.12 ± 0.23 cm2/m2 vs. TAVI 1.17 ± 0.28 cm2/m2, P=0.265), mean transvalvular gradients (SUAVR 12.9 ± 5.3 mmHg vs. TAVI 12.2 ± 6.2 mmHg, P=0.332), and moderate-to-severe PPM (SUAVR 4.1% vs. TAVI 8.9%, P=0.096). TAVI group showed a higher cumulative incidence of MACCEs at 36 months (SUAVR 18.1% vs. TAVI 32.6%, P<0.001). Pacemaker implantation (PMI) and perivalvular leak ≥ 2 were significantly higher in TAVI group and identified as independent predictors of mortality (PMI: hazard ratio [HR] 3.05, 95% confidence interval [CI] 1.34-6.94, P=0.008; PPM: HR 2.72, 95% CI 1.25-5.94, P=0.012).

Conclusion: In patients with SAA, SUAVR and TAVI showed comparable hemodynamic performances. Moreover, all-cause death and incidence of MACCEs at follow-up were significantly higher in TAVI group.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11259373PMC
http://dx.doi.org/10.21470/1678-9741-2023-0155DOI Listing

Publication Analysis

Top Keywords

aortic valve
20
valve replacement
12
sutureless aortic
8
transcatheter aortic
8
valve implantation
8
patients small
8
small aortic
8
aortic annulus
8
hemodynamic performances
8
saa underwent
8

Similar Publications

Aneurysm rupture is a life-threatening event, yet its underlying mechanisms remain largely unclear. This study investigated the fracture properties of the thoracic aneurysmatic aorta (TAA) using the symmetry-constraint Compact Tension (symconCT) test and compared results to native and enzymatic-treated porcine aortas' tests. With age, the aortic stiffness increased, and tissues ruptured at lower fracture energy [Formula: see text].

View Article and Find Full Text PDF

Introduction: Calcific aortic valve disease (CAVD) is increasingly prevalent among the aging population, and there is a notable lack of drug therapies. Consequently, identifying novel drug targets will be of utmost importance. Given that type 2 diabetes is an important risk factor for CAVD, we identified key genes associated with diabetes - related CAVD via various bioinformatics methods, which provide further potential molecular targets for CAVD with diabetes.

View Article and Find Full Text PDF

Transjugular transcatheter edge-to-edge mitral valve repair in a patient with functional mitral regurgitation: a case report.

Eur Heart J Case Rep

January 2025

Department of Cardiovascular Medicine, Sendai Kousei Hospital, 1-20 Tsutsumidori-amamiya, Aoba Ward, Sendai, Miyagi 9810914, Japan.

Background: Transcatheter edge-to-edge mitral valve repair (M-TEER) using the MitraClip system is primarily performed using the transfemoral approach. However, when this approach is not feasible, the transjugular approach can be used as an alternative.

Case Summary: A 57-year-old man presented with heart failure and persistent New York Heart Association class IV symptoms, refractory to guideline-directed medical therapy, intravenous therapy, and intra-aortic balloon pumping.

View Article and Find Full Text PDF

Aortic dissection (AoD) is a rare fatal condition in which tearing in the intima causes a false channel in the aorta and can lead to rupture. AoD is classified as the DeBakey classification (Types I, II, III) and Stanford classification (Types A and B). Women with underlying risk factors such as hypertension, smoking, bicuspid aortic valve, and connective tissue disorders are at risk for pregnancy-related AoD.

View Article and Find Full Text PDF

Background: Vascular and bleeding complications remain a concern after transfemoral transcatheter aortic valve replacement (TAVR). The impact of the sheath type on these complications remains unclear.

Methods: The prospective MARVEL registry study analyzed enrolled 500 patients undergoing large-bore transfemoral procedures and arteriotomy closure with the MANTA vascular closure device from 10 hospitals in Europe and Canada.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!