Background And Purpose: Arthroplasty surgeons traditionally assess cup orientation after total hip arthroplasty (THA) on supine radiographs. Contemporary hip-spine analyses provide information on standing, functional cup orientation. This study aims to (i) characterize cup orientations when supine and standing; (ii) determine orientation differences between postures; and (iii) identify factors associated with magnitude of orientation differences.

Methods: This is a 2-center, multi-surgeon, prospective, consecutive cohort study. 419 primary THAs were included (57% women; mean age: 64 years, standard deviation [SD] 11). All patients underwent supine and standing antero-posterior pelvic and lateral spinopelvic radiographs. Cup orientation and spinopelvic parameters were measured. Target cup orientation was defined as inclination/anteversion of 40°/20° ± 10°. A change in orientation (Δinclination/Δanteversion) between postures > 5° was defined as clinically significant. Variability was defined as 2 x SD.

Results: Inclination increased from 40° (supine) to 42° (standing) corresponding to a Δinclination of 2° (95% confidence interval [CI] 2-3). Anteversion increased from 25° (supine) to 30° (standing) corresponding to a Δanteversion of 5° (CI 5-6). When supine, 69% (CI 65-74) of THAs were within target, but only 44% (CI 39-49) were within target when standing, resulting in a further 26% (CI 21-30) being out of target when standing. From supine to standing, a clinically significant change in anteversion (> 5°) was seen in 47% (CI 42-52) of cases. Δanteversion was higher in women than in men (6°, CI 5-7 vs 5°, CI 4-5) corresponding to a difference of 1° (CI 1-2), which was dependent on tilt change, standing cup anteversion, age, and standing pelvic tilt.

Conclusion: Cup inclination and version increase upon standing but significant variability exists due to patient factors.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11261814PMC
http://dx.doi.org/10.2340/17453674.2024.41091DOI Listing

Publication Analysis

Top Keywords

cup orientation
20
supine standing
16
standing
12
orientation
8
supine
8
cohort study
8
study 419
8
total hip
8
standing corresponding
8
target standing
8

Similar Publications

Accurate acetabular component positioning is crucial for the success of total hip arthroplasty (THA). Malplacement of the acetabular component increases the risk of post-surgery complications, most notably dislocation.1 Furthermore, malposition can also result in wear of the polyethylene liner, limited range of motion, and osteolysis.

View Article and Find Full Text PDF

Background: Proper positioning of a total hip arthroplasty (THA) plays a crucial role in the success and long-term survivorship of the implant. Cup positioning within the Lewinnek Safe Zone (LSZ) does not, however, avoid implant dislocation. Thus, the concept of a functional cup position has been introduced.

View Article and Find Full Text PDF

Aims: Excellent outcomes have been reported following CT-based robotic arm-assisted total hip arthroplasty (rTHA) compared with manual THA; however, its superiority over CT-based navigation THA (nTHA) remains unclear. This study aimed to determine whether a CT-based robotic arm-assisted system helps surgeons perform accurate cup placement, minimizes leg length, and offsets discrepancies more than a CT-based navigation system.

Methods: We studied 60 hips from 54 patients who underwent rTHA between April 2021 and August 2023, and 45 hips from 44 patients who underwent nTHA between January 2020 and March 2021 with the same target cup orientation at the Department of Orthopedic Surgery at Ozu Memorial Hospital, Japan.

View Article and Find Full Text PDF

Introduction: Robot-assisted instrumentation during total hip arthroplasty (THA) has the potential to improve acetabular cup positioning. This study aimed to evaluate the precision of robotic-arm-assisted THA (rTHA) and assess whether the system can provide accurate cup positioning comparable to conventional THA (cTHA).

Methods: A single-center prospective cohort study consisting of 151 patients who underwent THA (108 rTHA and 43 cTHA).

View Article and Find Full Text PDF
Article Synopsis
  • Researchers designed a new heterochiral structure by modifying a symmetric trimolecular bundle of aromatic helices, changing one helix's orientation and handedness.
  • They developed both rigid and flexible linkers to create a unimolecular version of this structure and synthesized model sequences for testing.
  • Various techniques, including nuclear magnetic resonance, circular dichroism, X-ray crystallography, and molecular dynamics simulations, confirmed the structural integrity and proper folding of the new unimolecular three-helix bundle.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!