Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
In this study, an environmentally sustainable fluorimetric method for determination of Vonoprazan fumarate (VON) in dosage forms using nanoprobes consisting of nitrogen and sulfur co-doped carbon quantum dots (N, S-CQDs). The N, S-CQDs were prepared through a microwave-assisted method in 30 s. The resulting N, S-CQDs were characterized using transmission electron microscopy (TEM), high-resolution transmission electron microscopy (HRTEM), Fourier transform infrared spectroscopy (FTIR), and X-ray photoelectron spectroscopy (XPS). They exhibit fluorescence emission at 460 nm after excitation at 385 nm with a high quantum yield (60%). The analytical approach for VON determination relies on the quenching effect exerted by VON on the native fluorescence intensity of CQDs. The quenching mechanism was investigated using Stern-Volmer plots. The proposed method demonstrates linearity across a concentration range 10-80 μM (4.6-36.8 μg/mL) with corresponding limits of detection and quantitation calculated as 2.17 μM (0.99 μg/mL) and 6.58 μM (3.02 μg/mL), respectively. The method has been effectively utilized for the determination of VON in the pharmaceutical samples. Statistical comparison with reported RP-HPLC has been performed to verify the accuracy and precision of the developed method. The environmental sustainability of the developed method has been thoroughly examined through various greenness metrics.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/bio.4834 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!