A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Axial length adjustment in eyes with silicone oil endotamponade reduces overestimation by a swept-source optical coherence tomography-based biometer. | LitMetric

Background: To assess changes in ocular biometry of the phakic eye after pars-plana-vitrectomy (PPV) and silicone oil (SO) endotamponade in eyes with a retinal detachment.

Methods: This retrospective, consecutive case series included 72 eyes of 72 patients who underwent PPV with 5000-centistokes SO endotamponade between July 2018 and June 2023. Pseudophakic eyes and eyes with a combined phacovitrectomy were excluded. Primary endpoints were keratometry values, anterior chamber depth (ACD), lens thickness (LT), horizontal corneal diameter (HCD), and axial length (AL) measured by swept-source optical coherence tomography-based biometry (IOLMaster 700) preoperatively and six weeks postoperatively. A recently described formula was used to adjust the AL (aAL) in eyes with SO endotamponade and a theoretical intraocular lens (IOL) calculation was performed.

Results: The mean age was 62.1 ± 8.3 years (range: 37-85). After PPV with SO fill, there was an increase in K (0.19 ± 0.51D), while ACD (0.05 ± 0.13 mm), LT (0.03 ± 0.14 mm), and HCD (0.02 ± 0.24 mm) decreased. Preoperatively, the mean AL was 25.22 ± 1.78 mm, while postoperatively the AL was overestimated by 0.12 ± 0.42 mm on average (p = 0.04). By adjusting the AL, the mean difference could be reduced to -0.002 ± 0.41 mm. The aAL resulted in a difference in the refractive outcome in eyes with an AL > 25 mm of 0.34 ± 0.10D in the IOL calculation.

Conclusions: While changes in biometry after PPV with SO endotamponade in the anterior segment are clinically less relevant, a considerable overestimation of AL with IOLMaster 700 was found. We recommend the use of a recently introduced formula for adjusting AL in eyes with SO, allowing overestimation to be minimised considerably.

Download full-text PDF

Source
http://dx.doi.org/10.1111/ceo.14418DOI Listing

Publication Analysis

Top Keywords

axial length
8
eyes
8
silicone oil
8
oil endotamponade
8
swept-source optical
8
optical coherence
8
coherence tomography-based
8
iolmaster 700
8
endotamponade
5
length adjustment
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!