A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

quantification of stent-graft behaviour during chimney thoracic endovascular aortic repair. | LitMetric

AI Article Synopsis

  • The study aimed to assess how double chimney thoracic endovascular aortic repair (ch-TEVAR) affects gutter phenomena and endograft deformations in a model that simulates real blood flow conditions.
  • Researchers compared two types of chimney grafts (balloon-expandable and self-expandable) using advanced imaging techniques to evaluate their behavior during different phases of the heart cycle.
  • Results showed that balloon-expandable grafts had significantly larger gutter volumes and exhibited different deformation patterns than self-expandable grafts, highlighting important design considerations for future devices to mitigate risks like endoleak.

Article Abstract

Objective: To quantify dynamic gutter phenomena and endograft deformations during double chimney thoracic endovascular aortic repair (ch-TEVAR) in a physiological model of the thoracic aorta subjected to pulsatile haemodynamic conditions.

Methods: Two procedures revascularizing the brachiocephalic trunk and left common carotid artery were performed representing both balloon-expandable (BE, Ankura-BeGraft) and self-expandable (SE, Ankura-Viabahn) double ch-TEVAR configurations. Retrospectively gated computed tomography (CT) was used to evaluate endograft behaviour. Device interactions were characterised according to gutter volume, gutter surface deviation, and endograft deformation (D-ratio) at end-diastolic and peak-systolic aortic pressure.

Results: Use of BE chimney grafts resulted in three times total gutter volume compared to SE chimney grafts. Gutter volumes were observed to vary dynamically between the end-diastolic and peak-systolic phases of the cardiac cycle, with the most substantial change associated with the BE configuration. Chimney graft deformations were dependent on device type, with SE devices exhibiting up to twice the deformation as BE devices. When adjacent, SE chimney grafts were observed to support each other, and thus tended towards a more consistently circular shape.

Conclusion: Gutter and chimney graft behaviour were dependent on device type, and exhibited both spatial and temporal variability. This study emphasises notable differences between BE and SE double ch-TEVAR configurations which should be considered when evaluating risk of endoleak. The findings reported here also support the use of gated CT to better identify device-related complications with ch-TEVAR, and can be used in the design of next generation devices.

Download full-text PDF

Source
http://dx.doi.org/10.1177/17085381241260910DOI Listing

Publication Analysis

Top Keywords

chimney grafts
12
chimney thoracic
8
thoracic endovascular
8
endovascular aortic
8
aortic repair
8
double ch-tevar
8
ch-tevar configurations
8
gutter volume
8
end-diastolic peak-systolic
8
chimney graft
8