Formation of Micelles by Nonionic Detergent Molecules Leads to the Breakthrough Peak in Reversed-Phase Ultraperformance Liquid Chromatography (UPLC).

Anal Chem

Center for Mass Spectrometry, Department of Chemistry and Chemical Biology, Stevens Institute of Technology, Hoboken, New Jersey 07030, United States.

Published: July 2024

A peculiar phenomenon known as "breakthrough" occurs under reversed-phase ultraperformance liquid chromatography (UPLC) conditions and has been under scrutiny for decades. This effect takes place when a large volume of analyte solution, prepared in a solvent with an eluotropic strength significantly higher than that of the initial mobile phase solvent, is injected. According to the literature, under specific experimental conditions, a substantial portion of solutes is carried by the mobile phase and detected near the dead time of the chromatographic system. This phenomenon is typically observed when the injected volume of a particular analyte is sufficiently large. However, the underlying physicochemical principles governing this phenomenon have remained elusive. We present evidence demonstrating that breakthroughs can occur even when injecting a sample of a neat solvent devoid of any solute. By mass spectrometric analysis, we identified the breakthrough peak to represent the nonionic detergent Triton. When columns are equilibrated with water, Triton molecules, present as impurities in filtered water, accumulate on the nonpolar stationary phase. Upon the introduction of a solvent with a stronger elution strength, Triton molecules retained on the stationary phase are removed. As detergents, these Triton molecules aggregate into micelles featuring a hydrophobic inner core and a hydrophilic outer shell. These hydrophilic micelles are carried by the polar mobile phase and detected as the breakthrough peak at the dead time of the chromatographic system. When analytes are present, a portion of the injected solutes is captured by the micelles and transported with the breakthrough plug. This assertion was verified and confirmed by liquid chromatography-mass spectrometry (LC-MS) analysis of a methanolic solution of perfluorooctanoic acid (PFOA). The mass spectra corresponding to the breakthrough plug featured a peak for the PFOA anion (/ 413) in addition to those for Triton.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.4c02375DOI Listing

Publication Analysis

Top Keywords

breakthrough peak
12
mobile phase
12
triton molecules
12
nonionic detergent
8
reversed-phase ultraperformance
8
ultraperformance liquid
8
liquid chromatography
8
chromatography uplc
8
volume analyte
8
phase detected
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!