Background: Precise anesthesia delivery helps ensure amnesia, analgesia, and immobility. Conventionally, the end-tidal anesthetic concentration is maintained through manual adjustment of the fresh gas flow and anesthetic vaporizer output. Some anesthesia delivery systems can deliver and maintain clinician-selected end-tidal anesthetic agent (EtAA) concentration using a modified closed-loop system. We evaluated the performance of an End-tidal Control (EtC) system on the Aisys CS 2 anesthesia machine (GE HealthCare). We hypothesized EtC anesthetic delivery would be noninferior to manually controlled anesthetic delivery.

Methods: The Multi-site Anesthesia randomized controlled STudy of End-tidal control compared to conventional Results (MASTER) Trial evaluated anesthetic delivery in 210 adult patients receiving inhaled anesthesia. Patients were randomized to either EtC or manual control (MC) anesthetic delivery. The primary objective was to determine whether, compared to conventional anesthesia practice, EtC achieves and maintains clinician-specified EtAA and end-tidal oxygen (Et o2 ) concentrations within defined noninferiority limits. Noninferiority was concluded if the lower limit of the 95% confidence interval (CI) of the difference between the percent duration within the acceptable range (5% of steady state or a margin of ~10% of each agent's minimum alveolar concentration) for EtC and MC was ≥ -5% for both EtAA and Et o2 . Secondary objectives included performance measures: response time: time required to attain 90% of the first desired EtAA, overshoot: amount the controller (or vaporizer delivery) exceeded the desired EtAA, and accuracy: average deviation from the desired EtAA.

Results: EtC achieved and sustained targeted EtAA and Et o2 concentrations within the noninferiority threshold. The EtAA was within 5% of the desired value 98% ± 2.05% of the time with EtC compared to 45.7% ± 31.7% of the time with MC (difference 52.3% [95% CI, 45.9%-58.6%], P < .0001). For Et o2 , EtC was within the noninferiority limit 86.3% ± 22.8% of the time compared with MC at 41% ± 33.3% ( P < .0001, difference 45.3% [95% CI, 36.1%-54.5%]). The median response time for achieving 90% of the initial EtAA desired value was 75 seconds with EtC and 158 seconds with MC ( P = .0013). EtC exhibited a median overshoot of 6.64% of the selected EtAA concentration, whereas MC often failed to reach the clinician's desired value. The difference in median percent deviation from desired EtAA value was 15.7% ([95% CI, 13.5%-19.0%], P < 0001).

Conclusions: EtC achieves and maintains the EtAA and Et o2 concentration in a manner that is noninferior to manually controlled anesthesia delivery.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11379356PMC
http://dx.doi.org/10.1213/ANE.0000000000007132DOI Listing

Publication Analysis

Top Keywords

anesthesia delivery
16
end-tidal control
12
etaa concentration
12
anesthetic delivery
12
desired etaa
12
etaa
11
manual control
8
anesthesia
8
delivery
8
randomized controlled
8

Similar Publications

Microtextured microneedles are tiny needle-like structures with micron-scale microtextures, and the drugs stored in the microtextures can be released after entering the skin to achieve the effect of precise drug delivery. In this study, the skin substitution model of Ogden's hyperelastic model and the microneedle array and microtexture models with different geometrical parameters were selected to simulate and analyse the flow of the microtexture microneedle arrays penetrating the skin by the finite-element method, and the length of the microneedles was determined to be 200 μm, the width 160 μm, and the value of the gaps was determined to be 420 μm. A four-pronged cone was chosen as the shape of microneedles, and a rectangle was chosen as the shape of the drug-carrying microneedle.

View Article and Find Full Text PDF

Mothers encounter several challenges to sustain breastfeeding until the recommended 6 months of age. There is limited evidence on the impact of women's labor pain experiences upon cessation of breastfeeding. We aimed to investigate the association between women's labor pain experiences, intrapartum interventions, and pre-birth psychological vulnerabilities and cessation of breastfeeding.

View Article and Find Full Text PDF

Background: Early rapid sequence induction of anaesthesia (RSI) and tracheal intubation for patients with airway or ventilatory compromise following major trauma is recommended, with guidance suggesting a 45-min timeframe. Whilst on-scene RSI is recommended, the potential time benefit offered by Helicopter Emergency Medical Services (HEMS) has not been studied. We compared the time from 999/112 emergency call to delivery of RSI between patients intubated either in the Emergency Department or pre-hospital by HEMS.

View Article and Find Full Text PDF

Purpose: To determine the reference values for the shock index (SI) in postpartum patients undergoing elective cesarean delivery with regional anesthesia.

Methods: This prospective study was conducted at our tertiary center between August 1, 2023, and March 1, 2024. We calculated the reference values for the SI within the first 48 h postpartum for patients who underwent elective cesarean delivery after the 34th week of gestation.

View Article and Find Full Text PDF

Venous Endothelial Cell Transcriptomic Profiling Implicates METAP1 in Preeclampsia.

Circ Res

December 2024

Cardiovascular Research Center, Massachusetts General Hospital, Boston. (C.C., P.X., Z.Y., Y.S., E.S.L., J.D.R., M.C.H.).

Background: Preeclampsia is a hypertensive disorder of pregnancy characterized by systemic endothelial dysfunction. The pathophysiology of preeclampsia remains incompletely understood. This study used human venous endothelial cell (EC) transcriptional profiling to investigate potential novel mechanisms underlying EC dysfunction in preeclampsia.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!