Article Abstract

Actiwatch devices are often used to estimate time in bed (TIB), but recently became commercially unavailable. Thigh-worn activPAL devices could be a viable alternative. We tested convergent validity between activPAL (CREA algorithm) and Actiwatch devices. Data were from free-living samples comprising 47 youth (3-16 valid nights/participant) and 42 adults (6-26 valid nights/participant) who wore both devices concurrently. On average, activPAL predicted earlier bedtimes and later risetimes compared to Actiwatch, resulting in longer overnight intervals (by 1.49 hours/night for youth and 0.67 hours/night for adults; both p < 0.001). TIB interruptions were predicted less commonly by activPAL (mean < 2 interruptions/night for both youth and adults) than Actiwatch (mean of 24-26 interruptions/night in both groups; both p < 0.001). Overnight intervals for both devices tended to overlap for lengthy periods (mean of 7.38 hours/night for youth and 7.69 hours/night for adults). Within these overlapping periods, the devices gave matching epoch-level TIB predictions an average of 87.9% of the time for youth and 84.3% of the time for adults. Most remaining epochs (11.8% and 15.1%, respectively) were classified as TIB by activPAL but not Actiwatch. Overall, the devices had fair agreement during the overlapping periods, but limited agreement when predicting interruptions, bedtime, or risetime. Future work should assess the criterion validity of activPAL devices to understand implications for health research. The present findings demonstrate that activPAL is not interchangeable with Actiwatch, which is consistent with their differing foundations (thigh inclination for activPAL versus wrist movement for Actiwatch).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11257610PMC
http://dx.doi.org/10.1123/jmpb.2023-0011DOI Listing

Publication Analysis

Top Keywords

actiwatch devices
12
activpal
9
convergent validity
8
time bed
8
actiwatch
8
activpal actiwatch
8
youth adults
8
adults actiwatch
8
devices
8
activpal devices
8

Similar Publications

Consistent direction despite wavering policy: reductions in resident physician extended duration shifts over 20 years.

Am J Med

January 2025

Division of Sleep and Circadian Disorders, Departments of Medicine and Neurology, Brigham and Women's Hospital, Boston, MA; Division of Sleep Medicine, Harvard Medical School, Boston, MA; Division of General Pediatrics, Department of Pediatrics, Boston Children's Hospital, Boston, MA; Department of Pediatrics, Harvard Medical School, Boston, MA.

We examined data from 17,498 physicians-in-training who reported on 92,662 months of work over a 20 year study interval that included three major revisions to work hour limits. Extended duration shifts (≥24 hours; EDS) are much less common than they used to be. On average, first-year resident physicians (PGY1s) currently work a total of 4 EDS per year and 3 EDS per month during months in which any EDS are worked.

View Article and Find Full Text PDF

Goal And Aims: One challenge using wearable sensors is nonwear time. Without a nonwear (e.g.

View Article and Find Full Text PDF

Background: The association between inflammatory bowel disease (IBD) activity and poor sleep quality is reported. However, most research subjectively investigated this issue and lacked long-term follow-up.

Objectives: Our study aimed to investigate the prevalence of sleep disturbance in IBD patients across disease activity and evaluate the long-term correlation between disease activity, sleep quality, and quality of life.

View Article and Find Full Text PDF

Background: Poor sleep is associated with longer recovery following adolescent concussion, making the longitudinal assessment of sleep important for monitoring recovery and identifying sleep disruptions. An important consideration for successful monitoring of sleep following concussion is the feasibility and adherence of a given sleep monitoring tool when used in an at-home environment. Understanding the usability of different sleep monitoring tools is essential for determining their applicability for longitudinal assessment in an ecologically valid environment.

View Article and Find Full Text PDF

Evaluation of two different wrist actigraphy devices in the adult population.

J Clin Sleep Med

January 2025

Departamento de Enfermedades Respiratorias, Facultad de Medicina, Pontificia Universidad Católica de Chile, Santiago, Chile.

Study Objectives: Actigraphy devices are used in sleep medicine. The Actiwatch 2 (Philips Respironics) was an example of a frequently used device in this field. Nevertheless, the discontinuation of this device has led to an increased necessity for the implementation of other available actigraphy methods capable of providing objective information.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!