Among refractive errors, astigmatism is the most common optical aberration, where refraction changes in different meridians of the eye. It causes blurred vision at any distance and includes corneal, lenticular, and retinal astigmatism. Cataract surgery used to cause a progressive increase in the pre-exisiting corneal astigmatism because of creating a surgically induced astigmatism, for example, a large size surgery incision. The development of surgical techniques during last decades has made cataract surgery interchange treat preoperative corneal astigmatism at time of surgery. Nowadays, three surgical approaches can be used. By placing a sutureless clear corneal incision on the steep meridian of the cornea, a preoperative corneal astigmatism less than 1.0 D can be corrected. Single or paired peripheral corneal relaxing incisions (PCRIs) provide 1.0-3.0 D corneal astigmatism correction. PCRIs are typically used for treating 1.0-1.5 D of regular corneal astigmatism, if more than 2.0 D, the risk of overcorrection and irregular astigmatism is increased. When toric intraocular lenses (IOLs) are unavailable in markets, PCRIs are still a reasonable option for patients with up to 3.0 D of pre-existing corneal astigmatism. Toric IOLs implantation can correct 1.0-4.5 D of corneal astigmatism. Several IOLs are approved to correct a high degree of corneal astigmatism with cylinder power up to 12.0 D. These approaches can be used alone or in combination.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11246944 | PMC |
http://dx.doi.org/10.18240/ijo.2024.07.23 | DOI Listing |
Purpose: The light adjustable lens (LAL) (RxSight, Aliso Viejo, CA) is a premium intraocular lens that allows for correction of residual refractive error and astigmatism following implantation. Herein, we describe the surgical approach and evaluate the visual outcomes of patients following scleral fixation of the LAL.
Methods: Retrospective, single-surgeon surgical case series of 3 patients (3 eyes) with intraocular lens complications, who underwent combined pars plana vitrectomy and sutureless needle assisted intrascleral haptic fixation of the LAL between April 2022, to August 2023.
Background: Lens implantation becomes a major concern in patients lacking posterior capsular support, but various methods are available for rehabilitation. In such patients, scleral-fixated intraocular lens (SFIOL) implantation is preferred due to its fewer complications and better simulation of the natural lens position. In this non-randomized retrospective clinical study, we aimed to assess visual outcomes after sutureless SFIOL implantation in aphakic patients and factors affecting visual outcomes.
View Article and Find Full Text PDFQuant Imaging Med Surg
January 2025
Aier Institute of Refractive Surgery, Refractive Surgery Center, Guangzhou Aier Eye Hospital, Guangzhou, China.
Background: Whether the correlations between anterior and posterior corneal parameters vary according to different conditions is unknown. We aimed to investigate the anterior-to-posterior correlations of corneal parameters according to different refractive status and anterior segment dimension.
Methods: A total of 8,365 myopic eyes undergoing refractive surgery between 2017 and 2019 from multiple ophthalmic centers were consecutively included in the study.
BMC Ophthalmol
January 2025
Department of Ophthalmology, Peking University Third Hospital, 49 North Garden Rd., Haidian District, Beijing, China.
Background: This study aims to comprehensively evaluate the predictive accuracy of six widely used toric intraocular lens (IOL) calculators in eyes undergoing cataract surgery with toric IOL implantation.
Methods: This retrospective study reviewed 53 eyes of 53 patients that underwent cataract extraction with toric IOL implantation using Zeiss 709 M. Six toric IOL calculators were evaluated: Barrett toric calculator (with predicted PCA, measured PCA, and TK), Kane formula (predicted PCA), and EVO 2.
Cont Lens Anterior Eye
January 2025
Department of Optics and Optometry and Vision Sciences, University of Valencia, 46100 Burjassot, Spain.
Purpose: The objective of this investigation was to consolidate the extant data pertaining to interocular astigmatic symmetry, with a view to discerning any patterns that may emerge from the research.
Methods: A systematic literature review was conducted in accordance with the PICO framework. The search, conducted through September 2024, included three databases (PubMed, Web of Science, and Scopus) and the reference list of the selected articles, which were identified from inception.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!