Background: The Childhood Trauma Questionnaire- Short Form (CTQ-SF) is among the most extensively studied and widely utilized instruments for evaluating childhood maltreatment.

Objective: The purpose of this study was to conduct a reliability generalization meta-analysis to estimate the average reliability of the CTQ-SF scores and its factors and search for study characteristics that can explain the variability in those coefficients.

Methods: A total of 39 independent samples provided 243 reliability estimates (Cronbach's alpha, McDonald's omega, and/or test-retest reliability coefficients) with the data at hand for the scores on the CTQ-SF and its five subscales for this meta-analysis.

Results: Random and mixed-effects models were employed for analyzing the data. The average Cronbach's alpha coefficient for the CTQ-SF total score was 0.891 (95 % CI: 0.868, 0.910). For the subscales, the average Cronbach's alpha coefficient ranged from 0.656 (Physical Neglect) to 0.916 (Sexual Abuse). The average McDonald's Omega coefficient for the CTQ-SF total score was 0.800 (95 % CI: 0.800 0.800). For the subscales, the average McDonald's Omega ranged from 0.740 (Physical Neglect) to 0.900 (Sexual Abuse). The average test-retest reliability for CTQ-SF total score was 0.788 (95 % CI: 0.635, 0.872), with the subscales ranging from 0.668 (Physical Neglect) to 0.709 (Physical Abuse). Moderator analyses revealed that some factors can affect reliability estimate.

Conclusions: Although CTQ-SF and its five subscales have shown adequate reliability, it may vary as a function of the variability of scores, geographical location, financial source, and the affiliation of the main researcher.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chiabu.2024.106941DOI Listing

Publication Analysis

Top Keywords

test-retest reliability
12
cronbach's alpha
12
mcdonald's omega
12
ctq-sf total
12
total score
12
physical neglect
12
reliability
9
reliability generalization
8
generalization meta-analysis
8
childhood trauma
8

Similar Publications

This study aimed to address the limitations of conventional methods for measuring skeletal muscle mass for sarcopenia diagnosis by introducing an artificial intelligence (AI) system for direct computed tomography (CT) analysis. The primary focus was on enhancing simplicity, reproducibility, and convenience, and assessing the accuracy and speed of AI compared with conventional methods. A cohort of 3096 cases undergoing CT imaging up to the third lumbar (L3) level between 2011 and 2021 were included.

View Article and Find Full Text PDF

Subject-specific parameters in lumped hemodynamic models of the cardiovascular system can be estimated using data from experimental measurements, but the parameter estimation may be hampered by the variability in the input data. In this study, we investigate the influence of inter-sequence, intra-observer, and inter-observer variability in input parameters on estimation of subject-specific model parameters using a previously developed approach for model-based analysis of data from 4D Flow MRI acquisitions and cuff pressure measurements. The investigated parameters describe left ventricular time-varying elastance and aortic compliance.

View Article and Find Full Text PDF

Sighting dominance is an important behavioral property which has been difficult to measure quantitatively with high precision. We developed a measurement method that is grounded in a two-camera model that satisfies these aims. Using a simple alignment task, this method quantifies sighting ocular dominance during binocular viewing, identifying each eye's relative contribution to binocular vision.

View Article and Find Full Text PDF

Introduction: Deep inspiration breath hold technique has shown promise in reducing cardiac toxicity and improving patient outcomes. However, there is a lack of consensus regarding the implementation of abdominal breath hold technique and its impact on cardiac dose. This systematic review and meta-analysis aim to provide insights into the comparative effectiveness of abdominal and thoracic breath hold in mitigating cardiac toxicity during radiation therapy for left-sided breast cancer.

View Article and Find Full Text PDF

To define training zones, ventilatory thresholds (VTs) are commonly established by cardiopulmonary gas-exchange analysis during incremental exercise tests. Portable near-infrared spectroscopy (NIRS) devices have emerged as a potential tool for detecting these thresholds by monitoring muscle oxygenation. This study evaluated the accuracy of NIRS measurements to determine VTs or critical power (CP) based on muscle oxygen saturation and assesses the device's consistency across 2 constant-load tests.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!