Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: We describe the development of 3D-printed stents using our digital workflow and their effects on patients enrolled in the lead-in phase of a multi-center, randomized Phase-II trial.
Materials And Methods: Digital dental models were created for patients using intraoral scanning. Digital processes were implemented to develop the mouth-opening, tongue-depressing, and tongue-lateralizing stents using stereolithography. Time spent and material 3D-printing costs were measured. Physicians assessed mucositis using the Oral Mucositis Assessment Scale (OMAS) and collected MD Anderson Symptom Inventory (MDASI) reports and adverse events (AEs) from patients at various time points (TPs). OMAS and MDASI results were evaluated using paired t-test analysis.
Results: 18 patients enrolled into the lead-in phase across 6 independent clinical sites in the USA. 15 patients received stents (average design and fabrication time, 8 h; average material 3D-printing cost, 11 USD). 10 eligible patients with complete OMAS and MDASI reports across all TPs were assessed. OMAS increased significantly from baseline to week 3 of treatment (mean difference = 0.34; 95 % CI, 0.09-0.60; p = 0.01). MDASI increased significantly from baseline to week 3 of treatment (mean difference = 1.02; 95 % CI, 0.40-1.70; p = 0.005), and week 3 of treatment to end of treatment (mean difference = 1.90; 95 % CI, 0.90-2.92; p = 0.002). AEs (grades 1-3) were reported by patients across TPs. Mucositis and radiation dermatitis were primarily attributed to chemoradiation.
Conclusions: 3D-printed stents were successfully fabricated and well tolerated by patients. As patients enroll in the randomized phase of this trial, data herein will establish a baseline for comparative analysis.