Introduction: Acute carotid-related stroke (CRS), with its large thrombo-embolic load and large volume of affected brain tissue, poses significant management challenges. First generation (single-layer) carotid stents fail to insulate the athero-thrombotic material; thus they are often non-optimized (increasing thrombosis risk), yet their use is associated with a significant (20-30%) risk of new cerebral embolism.
Aim: To evaluate, in a multi-center multi-specialty investigator-initiated study, outcomes of the MicroNET-covered (cell area ≈ 0.02-0.03 mm) carotid stent (CGuard, InspireMD) in consecutive CRS patients eligible for emergency recanalization. Treatment, other than study device use, was according to center/operator routine.
Material And Methods: Seventy-five patients (age 40-89 years, 26.7% women) were enrolled in 7 interventional stroke centers.
Results: The median Alberta Stroke Program Early CT Score (ASPECTS) was 9 (6-10). Study stent use was 100% (no other stent types implanted); retrograde strategy predominated (69.2%) in tandem lesions. Technical success was 100%. Post-dilatation balloon diameter was 4.0 to 8.0 mm. 89% of patients achieved final modified Thrombolysis in Cerebral Infarction (mTICI) 2b-c/3. Glycoprotein IIb/IIIa inhibitor use as intraarterial (IA) bolus + intravenous (IV) infusion was an independent predictor of symptomatic intracranial hemorrhage (OR = 13.9, 95% CI: 5.1-84.5, < 0.001). The mortality rate was 9.4% in-hospital and 12.2% at 90 days. Ninety-day mRS0-2 was 74.3%, mRS3-5 13.5%; stent patency was 93.2%. Heparin-limited-to-flush predicted patency loss on univariate (OR = 14.3, 95% CI: 1.5-53.1, < 0.007) but not on multivariate analysis. Small-diameter balloon/absent post-dilatation was an independent predictor of stent patency loss (OR = 15.2, 95% CI: 5.7-73.2, < 0.001).
Conclusions: This largest to-date study of the MicroNET-covered stent in consecutive CRS patients demonstrated a high acute angiographic success rate, high 90-day patency and favorable clinical outcomes despite variability in procedural strategies and pharmacotherapy (SAFEGUARD-STROKE NCT05195658).
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11249880 | PMC |
http://dx.doi.org/10.5114/aic.2024.140963 | DOI Listing |
Postepy Kardiol Interwencyjnej
September 2024
Department of Neurosurgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York, USA.
Postepy Kardiol Interwencyjnej
September 2024
St. John Paul II Hospital in Krakow, Stroke Thrombectomy-Capable Cardiovascular Centre, Krakow, Poland.
Postepy Kardiol Interwencyjnej
June 2024
St. John Paul II Hospital in Krakow Stroke Thrombectomy-Capable Cardiovascular Centre, Krakow, Poland.
Introduction: Acute carotid-related stroke (CRS), with its large thrombo-embolic load and large volume of affected brain tissue, poses significant management challenges. First generation (single-layer) carotid stents fail to insulate the athero-thrombotic material; thus they are often non-optimized (increasing thrombosis risk), yet their use is associated with a significant (20-30%) risk of new cerebral embolism.
Aim: To evaluate, in a multi-center multi-specialty investigator-initiated study, outcomes of the MicroNET-covered (cell area ≈ 0.
J Cardiovasc Surg (Torino)
June 2024
Stroke Thrombectomy-Capable Center, St. John Paul II Hospital, Krakow, Poland.
Background: Carotid-related strokes (CRS) are largely unresponsive to intravenous thrombolysis and are often large and disabling. Little is known about contemporary CRS referral pathways and proportion of eligible patients who receive emergency mechanical reperfusion (EMR).
Methods: Referral pathways, serial imaging, treatment data, and neurologic outcomes were evaluated in consecutive CRS patients presenting over 18 months in catchment area of a major carotid disease referral center with proximal-protected CAS expertise, on-site neurology, and stroke thrombectomy capability (Acute Stroke of CArotid Artery Bifurcation Origin Treated With Use oF the MicronEt-covered CGUARD Stent - SAFEGUARD-STROKE Registry; companion to SAFEGUARD-STROKE Study NCT05195658).
J Cardiovasc Surg (Torino)
June 2024
Vascular Surgery Unit, Sant'Eugenio Hospital, Rome, Italy.
Background: The study aims to evaluate the association of proximal flow-inversion cerebral protection and MicroNet-covered CGuard stents in reducing early and late embolic events in carotid artery stenting procedures.
Methods: From 2018 to 2023, we performed 204 procedures in 180 patients with flow inversion cerebral protection and CGuard stents at the Vascular Surgery Unit of Sant'Eugenio Hospital in Rome. Cerebral protection was achieved with a Flow-Gate2 catheter connected to a peripheral vein.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!