Background: During the heart cycle, the left ventricle (LV) not only shows a contraction-relaxation pattern, but LV has a rotational mechanics, as well. It is a known fact that certain pathologies may be associated with an absence of LV twist, when LV basal and apical regions rotate in the same clockwise (cw) or counterclockwise (ccw) direction called LV 'rigid body rotation' (LV-RBR), but it can also occur in healthy subjects. The present cohort study aimed to examine LV strains in healthy subjects with LV-RBR versus with normally directed LV rotational mechanics by three-dimensional speckle-tracking echocardiography (3DSTE).
Methods: The study consisted of 181 healthy individuals, from which 171 cases had normally directed LV rotational mechanics (mean age: 32.5±12.3 years, 79 males) and 10 healthy subject showed LV-RBR (mean age: 35.4±11.3 years, 3 males). Complete two-dimensional (2D) Doppler echocardiography and 3DSTE were performed in all healthy individuals.
Results: None of routine 2D Doppler echocardiographic parameters showed differences between the groups examined. There were no subjects with ≥ grade 1 regurgitation on any valves or with significant stenosis on any valves. 3DSTE-derived LV volumes, global and mean segmental strains did not differ between the groups examined. Apical anterior and lateral segments showed reduced segmental LV circumferential strain (CS) (-18.9%±8.5% -26.7%±10.7%, P=0.02; -27.3%±12.6% -34.8%±13.2%, P=0.08, respectively) and LV area strain (AS) (-26.8%±9.8% -36.8%±12.0%, P=0.01; -35.7%±13.2% -45.0%±14.6%) in healthy subjects having LV-RBR as compared to cases with normally directed LV rotational mechanics. These abnormalities were present only in subjects having cwLV-RBR.
Conclusions: Although global LV deformation is normal in the presence of LV-RBR in healthy adults, reduction of apical anterior and lateral LV-CS (and LV-AS) are present in cases with cwLV-RBR only suggesting segmental deformation abnormalities.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11250327 | PMC |
http://dx.doi.org/10.21037/qims-24-140 | DOI Listing |
Front Bioeng Biotechnol
January 2025
Department of Orthopaedics, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical Universit, Guangzhou, China.
Objective: The aim of this study is to assess the kinematic changes in the knee joint during walking in patients with isolated PCL-deficiency (PCLD) to determine the presence of walking-related joint instability (mechanical instability-abnormal displacement form structural damage). Additionally, the study seeks to provide biomechanical insights into the observed differences between subjective and objective assessments.
Methods: 35 healthy volunteers and 27 patients with isolated PCLD (both involved and uninvolved sides) were included in the study.
Front Sports Act Living
January 2025
Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam, Netherlands.
Background: It is assumed that the tennis serve is performed according to the kinetic chain principle in which a proximal-to-distal sequence in peak angular velocities of subsequent body segments can be observed to reach high end point ball velocities. The aim of the present study was to investigate if the magnitude and (intersegmental) timing of peak angular velocities of body segments in professional tennis players are different between first and second serves and if they are associated with serve performance.
Methods: Eight (two female and six male) professional tennis players performed each 48 tennis serves on a tennis court.
Adv Mater
January 2025
School of Materials Science and Engineering, Sun Yat-sen University, Guangzhou, 510275, China.
Mechanical force attracts booming attention with the potential to tune the tumor cell behavior, especially in cell migration. However, the current approach for introducing mechanical input is difficult to apply in vivo. How the mechanical force affects cell behavior in situ also remains unclear.
View Article and Find Full Text PDFHeliyon
January 2025
Advanced Technologies of Machine Tools (ATMT) Lab, Faculty of Mechanical Engineering, Tarbiat Modares University, Tehran, Iran.
Electrochemical grinding (ECG) offers advantages such as burr-free and stress-free material removal. Despite its proven potential, limited research has addressed the comprehensive effects of key process parameters on the surface integrity of AISI 304 stainless steel, particularly for applications requiring high-quality finishes, such as medical components. This study bridges this gap by systematically investigating the influence of ECG key parameters including voltage, rotational speed, and electrolyte concentration on main surface integrity parameters including current density, surface roughness, microhardness, and surface texture.
View Article and Find Full Text PDFNPJ Regen Med
January 2025
Department of Orthopedic Surgery, Columbia University, New York, NY, USA.
A high prevalence of rotator cuff tears presents a major clinical challenge. A better understanding of the molecular mechanisms underlying enthesis development and healing is needed for developing treatments. We recently identified hedgehog (Hh)-lineage cells critical for enthesis development and repair.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!