Purpose: To investigate the inhibition of myopia progression and axial elongation in children wearing orthokeratology (OK) lenses, as well as to evaluate the status of corneal reshaping, this study explores the relationship between changes in central corneal curvature (K-value) and e-value induced by OK lenses and axial elongation.
Methods: In this study, it is planned to select children aged 8-15 who wear orthokeratology lenses at the Pediatric Ophthalmology and Strabismus Clinic of the Second Affiliated Hospital of Dalian Medical University. All children will undergo slit lamp examination, visual acuity assessment, computerized refraction, intraocular pressure measurement, biometry, and corneal topography examination before lens wear and at 1 month, 3 months, and 6 months after lens wear in the pediatric ophthalmology clinic. Based on age (lower age group (8 < age ≤12 years); higher age group (12 < age ≤15 years)) and baseline equivalent spherical (SE) value (mild myopia group (-1.00 D < SE ≤ -3.25D); moderate myopia group (-3.25 D < SE ≤ -6.00 D)), four groups will be formed by pairing these factors. Suitable data will be selected according to inclusion and exclusion criteria, and different groups will be included. Data will be organized, and statistical analysis will be performed using SPSS software to obtain the results. The expected results will be discussed and analyzed.
Results: After wearing OK lenses, all four groups achieved good visual acuity at follow-up. At 6 months, there were no significant differences in visual acuity among the four groups ( = 0.149, >0.05). There were no significant differences in refractive error among the four groups ( = 0.066, >0.05). Baseline axial length differed significantly among the four groups ( = 0.000, <0.001), with the LM group having longer axial length than the LL group (P < 0.001, paired samples -test), and the HM group having longer axial length than the HL group ( < 0.001, paired samples -test). However, there were no significant differences in axial length change compared to baseline among the groups at 1 month, 3 months, and 6 months ( = 0.053; = 0.557; = 0.329, >0.05). Significant differences were observed in corneal flat K-value change compared to baseline among the four groups at 1 month, 3 months, and 6 months ( = 0.001, = 0.001, = 0.004, <0.05). There were no significant differences in e-value change among the groups at 1 and 3 months ( = 0.205, = 0.252, >0.05), but significant differences were found in e-value change compared to baseline at 6 months ( = 0.010, <0.05). Multiple regression analysis with changes in central corneal flat K-value and e-value as independent variables and axial elongation as the dependent variable showed a correlation between e-value change at 6 months and axial elongation ( = 0.004, <0.05), indicating a negative correlation.
Conclusion: Orthokeratology (OK) lenses effectively improve myopic children's vision by reshaping the cornea, leading to reduced central corneal curvature and flattening of its anterior surface. The effectiveness of OK lenses is not significantly affected by age or initial myopia severity. Children of varying ages and myopia levels experience similar levels of axial length control with OK lens wear. Changes in corneal shape due to OK lenses affect axial elongation, with greater changes in corneal morphology associated with smaller increases in axial length.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11253518 | PMC |
http://dx.doi.org/10.1016/j.heliyon.2024.e33341 | DOI Listing |
Adv Exp Med Biol
January 2025
Department of Optometry, University of Benin, Benin City, Nigeria.
Contact lenses have become integral tools in the realm of ocular therapeutics, extending beyond their primary function of refractive correction to encompass a diverse array of therapeutic applications. This review explores the evolving role of contact lenses in managing various ocular conditions, highlighting their efficacy in enhancing patient outcomes. Initially developed to correct refractive errors, contact lenses now serve as effective vehicles for delivering medications directly to the ocular surface, offering targeted treatment for conditions such as dry eye syndrome and corneal ulcers.
View Article and Find Full Text PDFJ Clin Med
November 2024
Ophthalmology Department, LaserVision Ambulatory Eye Surgery Unit, 11521 Athens, Greece.
To report a novel application within the USA of excimer ablation for the normalization of central corneal refractive irregularity, combined with higher fluence CXL in the effective management and visual rehabilitation of progressive keratoconus. 17 consecutive cases with progressive keratoconus were treated with corneal surface excimer laser ablation normalization using topography-guided (Contura) myopic ablation for customized corneal re-shaping with a 6 mm optical zone. The epithelial removal was accounted for by adding a -2.
View Article and Find Full Text PDFJ Biophotonics
December 2024
Studio Italiano di Oftalmologia, Rome, Italy.
This study investigated the effect of a theranostic-guided UV-A light corneal photo-reshaping technique on corneal elevation and wavefront aberration (WA) in human donor eyes. A specialized platform, combining UV-A light with corneal iontophoresis for controlled, patterned, riboflavin delivery, was used for both distribution assessment and concentration-driven photopolymerization of corneal proteins. In all cases, a consistent riboflavin concentration gradient, with lower levels in the central prepupillary zone, was recorded.
View Article and Find Full Text PDFInt J Pharm
January 2025
Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, 200 Columbia Street West, Waterloo, ON N2L 3G1, Canada; Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong. Electronic address:
3D printing, also known as additive manufacturing, continues to reshape manufacturing paradigms in healthcare by providing customized on-demand object fabrication. However, stereolithography-based 3D printers encounter a conflict between optimizing printing parameters, requiring more time, and print efficiency, requiring less time. Moreover, commonly used metrics to assess shape fidelity of 3D printed hydrogel materials like 'circularity' and 'printability' are limited by the soft nature of hydrogels, that can cause irregularities in their boundary.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!