A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Insights into two-phase flow dynamics in closed-loop pulsating heat pipes utilizing FeO/water: experimental visualization study. | LitMetric

This article discusses a focused study on visualizing the flow patterns in a two-phase pulsating heat pipe (PHP) using FeO/water as the working fluid at 3 V/V% concentration. The research also aims to meticulously examine phase change phenomena in the heating section, particularly focusing on bubble formation and expansion processes. A high-speed video camera was utilized to capture dynamic insights into the behavior of the FeO/water mixture. Based on the findings, a straightforward model was developed to explain bubble generation and growth in the mixture, serving as a useful reference for future PHP designs and optimizations. Visual observations also noted the stable nature of the FeO/water nanofluid over a 4-day period, confirming its consistency throughout the experiments. Moreover, the impact of heat load variation on the evaporator section was assessed using controlled heat inputs ranging from 10 to 80 W. Observations on the arrangement of slugs and plugs at a 50% filling ratio revealed interesting self-adjusting flow patterns in response to increasing heat inputs, providing valuable insights into PHP operational dynamics. Notably, the oscillatory flow behavior of FeO/water, the chosen working fluid, exhibited greater activity in comparison to water. This distinctive flow behavior contributed to achieving heightened thermal performance efficiency for the FeO/water system, attributed to its faster attainment of the annular flow condition.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11255214PMC
http://dx.doi.org/10.1038/s41598-024-67637-yDOI Listing

Publication Analysis

Top Keywords

pulsating heat
8
flow patterns
8
working fluid
8
behavior feo/water
8
heat inputs
8
flow behavior
8
flow
6
feo/water
6
heat
5
insights two-phase
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!