Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
This article discusses a focused study on visualizing the flow patterns in a two-phase pulsating heat pipe (PHP) using FeO/water as the working fluid at 3 V/V% concentration. The research also aims to meticulously examine phase change phenomena in the heating section, particularly focusing on bubble formation and expansion processes. A high-speed video camera was utilized to capture dynamic insights into the behavior of the FeO/water mixture. Based on the findings, a straightforward model was developed to explain bubble generation and growth in the mixture, serving as a useful reference for future PHP designs and optimizations. Visual observations also noted the stable nature of the FeO/water nanofluid over a 4-day period, confirming its consistency throughout the experiments. Moreover, the impact of heat load variation on the evaporator section was assessed using controlled heat inputs ranging from 10 to 80 W. Observations on the arrangement of slugs and plugs at a 50% filling ratio revealed interesting self-adjusting flow patterns in response to increasing heat inputs, providing valuable insights into PHP operational dynamics. Notably, the oscillatory flow behavior of FeO/water, the chosen working fluid, exhibited greater activity in comparison to water. This distinctive flow behavior contributed to achieving heightened thermal performance efficiency for the FeO/water system, attributed to its faster attainment of the annular flow condition.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11255214 | PMC |
http://dx.doi.org/10.1038/s41598-024-67637-y | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!