Ankle push-off power plays an important role in healthy walking, contributing to center-of-mass acceleration, swing leg dynamics, and accounting for 45% of total leg power. The majority of existing passive energy storage and return prostheses for people with below-knee (transtibial) amputation are stiffer than the biological ankle, particularly at slower walking speeds. Additionally, passive devices provide insufficient levels of energy return and push-off power, negatively impacting biomechanics of gait. Here, we present a clinical study evaluating the kinematics and kinetics of walking with a microprocessor-controlled, variable-stiffness ankle-foot prosthesis (945 g) compared to a standard low-mass passive prosthesis (Ottobock Taleo, 463 g) with 7 study participants having unilateral transtibial amputation. By modulating prosthesis stiffness under computer control across walking speeds, we demonstrate that there exists a stiffness that increases prosthetic-side energy return, peak power, and center-of-mass push-off work, and decreases contralateral limb peak ground reaction force compared to the standard passive prosthesis across all evaluated walking speeds. We demonstrate a significant increase in center-of-mass push-off work of 26.1%, 26.2%, 29.6% and 29.9% at 0.75 m/s, 1.0 m/s, 1.25 m/s, and 1.5 m/s, respectively, and a significant decrease in contralateral limb ground reaction force of 3.1%, 3.9%, and 3.2% at 1.0 m/s, 1.25 m/s, and 1.5 m/s, respectively. This study demonstrates the potential for a quasi-passive microprocessor-controlled variable-stiffness prosthesis to increase push-off power and energy return during gait at a range of walking speeds compared to a passive device of a fixed stiffness.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11255255PMC
http://dx.doi.org/10.1038/s41598-024-67230-3DOI Listing

Publication Analysis

Top Keywords

walking speeds
20
push-off power
12
energy return
12
variable-stiffness prosthesis
8
speeds compared
8
compared passive
8
passive device
8
transtibial amputation
8
microprocessor-controlled variable-stiffness
8
compared standard
8

Similar Publications

Objective: This study aimed to analyze the effect of a novel supervised exercise therapy (SET) program based on intermittent treadmill walking and circuit-based moderate-intensity functional training (MIFT) on walking performance and HRQoL in PAD patients.

Design: All participants underwent a 12-week SET that involved 15 to 30 minutes of treadmill walking followed by a 15-minute moderate-intensity functional training (MIFT) continued by 12-week of follow-up. Maximum walking distance (MWD), pain-free walking distance (PFWD), gait speed and estimated peak oxygen uptake (peak VO2) were calculated through the 6-minute walk test (6-MWT) and HRQoL through the Short Form-36 (SF-36) and the Vascular Quality of Life Questionnaire-6 (VascuQol-6).

View Article and Find Full Text PDF

This study aimed to determine the association between chronic schizophrenia, extrapyramidal symptoms (EPSs), body composition, nutritional status, and dynapenia/sarcopenia. Data from 68 chronic patients with schizophrenia were analyzed using Spearman's rho correlation coefficients, Kruskal-Wallis test, Mann-Whitney U test, and Cramér's V statistics. Among the participants, 32.

View Article and Find Full Text PDF

Background: Older adults with cancer are vulnerable to declines in muscle performance (e.g., strength, speed, duration of muscular contraction), which are associated with worse cancer-related outcomes.

View Article and Find Full Text PDF

Enhancing gait mechanics: The effectiveness of a novel walking aid.

J Orthop Sci

January 2025

Department of Orthopaedic Surgery, Wakayama Medical University, 811-1 Kimiidera, Wakayama City, Wakayama, 641-8509, Japan.

Background: A walking support orthosis known as the e-foot®, a rubber orthotic worn from the hip to the forefoot to enhance joint flexibility and movement, has been developed to assist elderly people and individuals with walking impairments. Despite its widespread acceptance and positive reception in some care settings, the precise impact of this device on gait dynamics remains unexplored. This study aims to bridge this gap by comparing the walking speeds of healthy volunteers using the e-foot® against their normal walking speeds.

View Article and Find Full Text PDF

Pilot study of the sequential square mat "Fisior® program": A strategy for improving mobility in older adults.

Geriatr Nurs

January 2025

Universidad de San Martin de Porres, Facultad de Medicina Humana, Centro de Investigación del Envejecimiento, Lima, Perú.

Objective: The present study aims to analyze the effectiveness of a gait re-education program using a sequential square mat (Tapiz Fisior®, in advance SSM Fisior®) in aspects related to mobility, balance, muscle strength, and gait of elderly people.

Methods: The intervention lasted eight weeks through progressive resistance training designed specifically for older people, with an approximate duration of 30-40 min, and was carried out three times a week on non-consecutive days using the SSM Fisior®.

Result: The intervention improved gait, balance, physical performance, lower limb strength, and walking speed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!