A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Rapid deployment aortic valve implantation in complex patients with infective endocarditis or aortic valve insufficiency. | LitMetric

Background: New prosthetic valves and surgical approaches that shorten operation time and improve the outcome of patients with aortic valve (AV) infective endocarditis (IE) and AV insufficiency (AVI) are crucial. The aim of this study was to evaluate the outcome of patients with AV IE or AVI treated with the EDWARDS INTUITY Rapid-Deployment AV prosthesis for this off-label indication.

Methods: This single-centre retrospective study analyzed data from patients who underwent AV replacement with the EDWARDS INTUITY Rapid-Deployment AV prosthesis for AV IE or regurgitation. (n = 8 for IE and n = 6 for AVI).

Results: Heart-lung machine times were significantly shorter in the AVI group (111.3 ± 20.7 min) compared to the IE group (171.9 ± 52.4 min) (p = 0.02). Aortic cross-clamp followed a similar trend (73.7 ± 9.9 min for AVI vs. 113.4 ± 35.6 min for IE) (p = 0.02). The length of ICU stay was also shorter in the AVI group (3.8 ± 2.6 days) compared to the IE group (16.9 ± 8.9 days) (p = 0.005). Postoperative echocardiography revealed no paravalvular leakage or significant valvular dysfunction in any patient. One patient died postoperatively from aspiration pneumonia.

Conclusion: The INTUITY valve demonstrates as a safe option for complex AV IE and AVI surgery. Further prospective studies with larger patient cohorts are necessary to confirm these findings and explore the long-term benefits of this approach.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11250961PMC
http://dx.doi.org/10.1186/s13019-024-02967-6DOI Listing

Publication Analysis

Top Keywords

aortic valve
12
infective endocarditis
8
outcome patients
8
edwards intuity
8
intuity rapid-deployment
8
rapid-deployment prosthesis
8
shorter avi
8
avi group
8
compared group
8
avi
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!