Metal artifacts notoriously pose significant challenge in computed tomography (CT), leading to inaccuracies in image formation and interpretation. Artifact reduction tools have been designed to improve cone beam computed tomography (CBCT) image quality by reducing artifacts caused by certain high-density materials. Metal artifact reduction (MAR) tools are specific algorithms that are applied during image reconstruction to minimize or eliminate artifacts degrading CBCT images. The purpose of the study is to evaluate the effect of a MAR algorithm on image quality in CBCT performed for evaluating patients before transarterial radioembolization (TARE). We retrospectively included 40 consecutive patients (aged 65 ± 13 years; 23 males) who underwent 45 CBCT examinations (Allura FD 20, XperCT Roll protocol, Philips Healthcare, Best, The Netherlands) in the setting of evaluation for TARE between January 2017 and December 2018. Artifacts caused by coils, catheters, and surgical clips were scored subjectively by four readers on a 5-point scale (1 = artifacts affecting diagnostic information to 5 = no artifacts) using a side-by-side display of uncorrected and MAR-corrected images. In addition, readers scored tumor visibility and vessel discrimination. MAR-corrected images were assigned higher scores, indicating better image quality. The differences between the measurements with and without MAR were most impressive for coils with a mean improvement of 1.6 points (95%CI [1.5 1.8]) on the 5-point likert scale, followed by catheters 1.4 points (95%CI [1.3 1.5]) and clips 0.7 points (95%CI [0.3 1.1]). Improvements for other artifact sources were consistent but relatively small (below 0.25 points on average). Interrater agreement was good to perfect (Kendall's W coefficient = 0.68-0.95) and was higher for MAR-corrected images, indicating that MAR improves diagnostic accuracy. A metal artifact reduction algorithm can improve diagnostic and interventional accuracy of cone beam CT in patients undergoing radioembolization by reducing artifacts caused by diagnostic catheters and coils, lowering interference of metal artifacts with adjacent major structures, and improving tumor visibility.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11252118 | PMC |
http://dx.doi.org/10.1038/s41598-024-66978-y | DOI Listing |
Invest Radiol
January 2025
From the Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany (Y.C.L., N.M., P.A.K., A.I., T.D., J.A.L., D.K.); and Siemens Healthineers AG, Erlangen, Germany (S.F., V.H., B.S.).
Objectives: The aim of this study was to assess the impact of an iterative metal artifact reduction (iMAR) algorithm combined with virtual monoenergetic images (VMIs) for artifact reduction in photon-counting detector computed tomography (PCDCT) during interventions.
Materials And Methods: Using an abdominal phantom, we conducted evaluations on the efficacy of iMAR and VMIs for mitigating image artifacts during interventions on a PCDCT. Four different puncture devices were employed under 2 scan modes (QuantumSn at 100 kV, Quantumplus at 140 kV) to simulate various clinical scenarios.
Imaging Sci Dent
December 2024
Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples Federico II, Naples, Italy.
Purpose: This study aimed to evaluate the impact of a metal artifact reduction (MAR) algorithm on cone-beam computed tomography (CBCT) scans of titanium and zirconia implants, both within and outside the field of view (FOV).
Materials And Methods: In this study, a dry human mandible was positioned in a CBCT scanner with only its left quadrant included in the FOV. Each type of implant (titanium and zirconia) was placed once in the right second premolar extraction socket and once in the left second premolar extraction socket of the mandible.
Biomater Transl
September 2024
Orthopaedic Research Institute and Department of Orthopaedics, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China.
Three-dimensional printed Ti-6Al-4V hemipelvic prosthesis has become a current popular method for pelvic defect reconstruction. This paper presents a novel biomimetic hemipelvic prosthesis design that utilises patient-specific anatomical data in conjunction with the Voronoi diagram algorithm. Unlike traditional design methods that rely on fixed, homogeneous unit cell, the Voronoi diagram enables to create imitation of trabecular structure (ITS).
View Article and Find Full Text PDFJ Magn Reson
December 2024
Univ. Lille, CNRS, Centrale Lille, Univ. Artois, UMR 8181, UCCS - Unité de Catalyse et Chimie du Solide, F-59000 Lille, France. Electronic address:
The two-dimensional (2D) refocused INADEQUATE NMR experiment, which correlates double-quantum (DQ) and single-quantum (SQ) coherences, is widely used to probe the chemical connectivities in solids. Nevertheless, the multiplets along the F dimension reduce the resolution and sensitivity of this experiment. The Composite-Refocusing (CR) technique with two excitation pulses has been proposed to suppress these multiplets in 2D INADEQUATE spectra of liquids.
View Article and Find Full Text PDFAdv Radiat Oncol
February 2025
Department of Radiation Oncology, University of Utah, Salt Lake City, Utah.
Purpose: To evaluate the image quality of an ultrafast cone-beam computed tomography (CBCT) system-Varian HyperSight.
Methods And Materials: In this evaluation, 5 studies were performed to assess the image quality of HyperSight CBCT. First, a HyperSight CBCT image quality evaluation was performed and compared with Siemens simulation-CT and Varian TrueBeam CBCT.