Background: Clamping along the transsyndesmotic (TS) axis decreases the risk of malreduction when reducing syndesmotic diastasis. We aimed to measure the difference between the TS axis and the axis determined by the newly proposed fluoroscopic incisura tangent (IT) method. The measurements were compared to those between the TS axis and those based on the center-center (CC) and talar dome lateral (TL) methods.
Methods: We analyzed computed tomographic images of 43 normal ankles. The IT view was simulated using a digitally reconstructed radiograph, in which the anterior and posterior fibular incisura tubercles overlapped on the internally rotated anteroposterior view. The interaxis angle between the TS and the axes determined by the IT method was measured on the axial computed tomographic image corresponding to the radiographic image. The same procedure was repeated using the CC and TL methods. The measured values were compared between the three methods using a one-factor analysis of variance. Furthermore, the measurements of the anteverted and retroverted incisurae were compared for each fluoroscopic method.
Results: The mean interaxis angles between the TS were - 0.5 degrees, 6.3 degrees, and - 1.8 degrees for the IT, CC, and TL methods, respectively, with a significantly larger value for the CC method than for the IT and TL methods (P < .001). No significant difference was found in the interaxis angle in the anteverted (-0.1 degrees) and retroverted (-1.0 degrees) incisurae when using the IT method (P = .15). The angles in the retroverted incisurae were larger than those of the anteverted incisurae for the CC and TL methods.
Conclusion: The fluoroscopic IT method accurately estimated the TS axis. The interaxis angles were consistent, regardless of the incisura anatomy. The fluoroscopic method can be used to clamp and fix the syndesmosis along the TS axis.
Level Of Evidence: Ⅳ.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.fas.2024.06.008 | DOI Listing |
Foot Ankle Surg
January 2025
Graduate School of Medical and Pharmaceutical Sciences, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba-shi, Chiba 260-8670, Japan.
Background: Clamping along the transsyndesmotic (TS) axis decreases the risk of malreduction when reducing syndesmotic diastasis. We aimed to measure the difference between the TS axis and the axis determined by the newly proposed fluoroscopic incisura tangent (IT) method. The measurements were compared to those between the TS axis and those based on the center-center (CC) and talar dome lateral (TL) methods.
View Article and Find Full Text PDFIndian J Orthop
January 2022
Department of Orthopaedic Surgery, Chosun University, Chosun University Hospital, 365 Pilmundae-ro, Dong-gu, Gwangju, 61453 Korea.
Background: To determine the optimal direction of the syndesmotic screw and to introduce a consistent landmark for practical application by analyzing three-dimensional (3D) modeling and virtual implantation.
Methods: A total of 105 cadaveric lower legs (50 males and 55 females; average height, 160.6 ± 7.
Foot Ankle Int
October 2013
Orthopaedic Trauma Institute, San Francisco General Hospital, University of California, San Francisco, CA, USA.
Background: Computed tomography (CT)-based indices may be superior to plain radiographs in determining the adequacy of reduction following operative fixation of the syndesmosis in unstable ankle fractures. This study assessed the reliability and accuracy of four CT-based methods for measurement of rotational malreduction of the fibula.
Methods: A simulated Weber C ankle fracture was created by performing an osteotomy in 9 cadaver ankles.