Objectives: There is extensive evidence to support the use of FIBTEM to identify hypofibrinogenemia during cardiac surgery, but less to support the use of EXTEM and INTEM clotting times (CTs) to identify other plasmatic coagulation factor deficiencies. The aim of the current study was to assess the diagnostic accuracy of EXTEM, INTEM, and HEPTEM CTs, using laboratory international normalized ratio (INR) and activated partial thromboplastin time (aPTT) as reference standards.

Design: This was a retrospective diagnostic accuracy study.

Setting: The work took place at a tertiary referral hospital.

Participants: A total of 176 cardiac surgical patients were enrolled.

Interventions: INR, aPTT, ROTEM EXTEM, INTEM, and HEPTEM were measured post-heparin reversal after cardiopulmonary bypass.

Measurements And Main Results: Sensitivity, specificity, and positive (PPVs) and negative predictive values (NPVs) for EXTEM CT >80 seconds and HEPTEM CT >280 seconds to detect INR ≥2.0, and INTEM CT >205 seconds to detect aPTT ≥38.5 seconds were calculated for all patients and the subset with normal FIBTEM A5 (>6 mm). The prevalence of INR ≥2.0 was 13%. EXTEM CT >80 seconds had a sensitivity of 1.00, specificity of 0.25, PPV of 0.17, and NPV of 1.00. HEPTEM CT >280 seconds had a sensitivity of 0.91, specificity of 0.38, PPV of 0.18, and NPV of 0.97. INTEM CT >205 seconds had a sensitivity of 0.97, specificity of 0.11, PPV of 0.57, and NPV of 0.75 for aPTT ≥38.5 seconds. These values were similar for the subset of patients with normal FIBTEM A5.

Conclusions: EXTEM CT >80 seconds and HEPTEM CT >280 seconds have high sensitivities and NPVs for INR >2.0, which would effectively "rule out" INR >2.0 as a cause for excessive bleeding. However, the low specificities and PPVs indicate they would be less effective in ruling it in. INTEM CT >205 seconds had low PPV and NPV in identifying aPTT >38.5 seconds.

Download full-text PDF

Source
http://dx.doi.org/10.1053/j.jvca.2024.06.031DOI Listing

Publication Analysis

Top Keywords

diagnostic accuracy
12
normal fibtem
12
extem intem
12
extem >80
12
seconds
12
>80 seconds
12
heptem >280
12
>280 seconds
12
intem >205
12
>205 seconds
12

Similar Publications

Background: Identifying patients with latent tuberculosis infection (LTBI) is challenging. This is particularly true amongst immunocompromised hosts, in whom the diagnostic accuracy of available tests is limited. The authors evaluated the impact of routine pretransplant review by a transplant infectious diseases (TID) physician on LTBI screening in allogeneic hematopoietic stem cell transplant (alloHSCT) recipients.

View Article and Find Full Text PDF

Efficient Orthogonal Spin Labeling of Proteins via Aldehyde Cyclization for Pulsed Dipolar EPR Distance Measurements.

J Am Chem Soc

December 2024

State Key Laboratory of Elemento-organic Chemistry, College of Chemistry, Nankai University, Tianjin 300071, China.

Pulsed dipolar electron paramagnetic resonance (PD-EPR) measurement is a powerful technique for characterizing the interactions and conformational changes of biomolecules. The extraction of these distance restraints from PD-EPR experiments relies on manipulation of spin-spin pairs. The orthogonal spin labeling approach offers unique advantages by providing multiple distances between different spin-spin pairs.

View Article and Find Full Text PDF

Digital PCR (dPCR) has transformed nucleic acid diagnostics by enabling the absolute quantification of rare mutations and target sequences. However, traditional dPCR detection methods, such as those involving flow cytometry and fluorescence imaging, may face challenges due to high costs, complexity, limited accuracy, and slow processing speeds. In this study, SAM-dPCR is introduced, a training-free open-source bioanalysis paradigm that offers swift and precise absolute quantification of biological samples.

View Article and Find Full Text PDF

Background And Study Aims: Diffuse infiltrative gastric cancer can be difficult to diagnose owing to a lack of endoscopic features in the superficial mucosa. Moreover, a forceps biopsy may not reveal a pathological diagnosis. We aimed to evaluate the diagnostic yield and safety of endoscopic mucosal resection (EMR) and 'open-lid submucosal biopsy', a technique wherein EMR followed by biopsy of the ulcer floor is performed for a pathological diagnosis.

View Article and Find Full Text PDF

Background: Metagenomic next-generation sequencing (mNGS) has emerged as a promising tool in clinical practice due to its unbiased approach to pathogen detection. Its diagnostic performance in pulmonary tuberculosis (PTB), however, remains to be fully evaluated.

Objective: This study aims to systematically review and Meta-analyze the diagnostic accuracy of mNGS in patients with PTB.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!