Olopatadine (OLP) is widely utilized as an effective antihistaminic drug for alleviating ocular itching associated with allergic conjunctivitis. With its frequent usage in pharmacies, there arises a pressing need for a cost-effective, easily implementable, environmentally sustainable detection method with high sensitivity. This study presents a novel signal-on fluorimetric method for detecting OLP in both its pure form and aqueous humor. The proposed approach depends on enhancing the weak intrinsic fluorescence emission of OLP, achieving a remarkable increase of up to 680% compared to its intrinsic fluorescence. This enhancement is achieved by forming micelles around protonated OLP using an acetate buffer (pH 3.6) and incorporating a solution of sodium dodecyl sulfate (SDS) surfactant. A strong correlation (R = 0.9996) is observed between the concentration of OLP and fluorescence intensities ranging from 1.0 to 100.0 ng mL with a limit of detection of 0.22 ng mL. This described method is successfully employed for quantifying OLP in both its powder form and pharmaceutical eye drops. Furthermore, it demonstrates robust performance in determining OLP in artificial aqueous humor with a percentage recovery of 99.05 ± 1.51, with minimal interference from matrix interferents. Moreover, the greenness of the described method was evaluated.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bio.4814DOI Listing

Publication Analysis

Top Keywords

aqueous humor
12
signal-on fluorimetric
8
intrinsic fluorescence
8
described method
8
olp
7
green sensitive
4
sensitive detection
4
detection olopatadine
4
olopatadine aqueous
4
humor signal-on
4

Similar Publications

Purpose: The aim of this study was to identify metabolic biomarkers and investigate the metabolic changes associated with aqueous humor in retinal vein occlusion macular edema (RVO-ME).

Methods: Aqueous humor (AH) samples were collected from patients, including those diagnosed with central retinal vein occlusion macular edema (CRVO-ME), branch retinal vein occlusion macular edema (BRVO-ME), and a control group undergoing cataract surgery. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) was utilized to analyze the metabolomic profiles in aqueous humor.

View Article and Find Full Text PDF

Treatment of pseudophakic aqueous misdirection syndrome.

Sci Rep

January 2025

Department of Ophthalmology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, 3010, Bern, Switzerland.

To describe the management and clinical course of 12 cases of pseudophakic aqueous misdirection syndrome (AMS). Twelve eyes of 12 Patients diagnosed with pseudophakic AMS between 2021 and 2022 were included. Best-corrected visual acuity, refraction, intraocular pressure (IOP), anti-glaucomatous medication, spectral domain ocular coherence tomography (SD-OCT) and postoperative complications were evaluated.

View Article and Find Full Text PDF

Purpose: To compare iridian Swept-Source Anterior Segment OCT (SS-AS-OCT) and microbiological features in Aqueous Humor (AH) in patients with Fuchs Uveitis Syndrome (FUS) and Posner-Schlossman Syndrome (PSS).

Methods: Comparative, retrospective-prospective single center study examining 131 eyes from 66 patients, including 33 eyes with PSS, 37 eyes with FUS, and 61 healthy eyes. AH samples were collected from affected eyes in all patients.

View Article and Find Full Text PDF

Purpose: To investigate the aqueous proteomics and metabolomics in low-energy and high-energy femtosecond laser-assisted cataract surgery (FLACS).

Methods: In this prospective observational study, 72 patients were randomized to 3 groups: low-energy FLACS, high-energy FLACS, and conventional phacoemulsification (controls). Aqueous was collected after femtosecond laser treatment or at the beginning of surgery (controls).

View Article and Find Full Text PDF

Purpose: Aqueous humor inflow rate, a key parameter influencing aqueous humor dynamics, is typically measured by fluorophotometry. Analyzing fluorophotometric data depends, inter alia, on the volume of aqueous humor in the anterior chamber but not the posterior chamber. Previous fluorophotometric studies of the aqueous inflow rate in mice have assumed the ratio of anterior:posterior volumes in mice to be similar to those in humans.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!