Introduction: Virtual reality cycling (VRC) is simulated outdoor cycling with changes in scenery in virtual reality (VR) with rotating ergometer pedals. The speed at which the scenery changes, which is the visual flow velocity, can shift according to the same pedal rotation speed.
Objectives: This study investigated the effects of different visual flow velocities on the psychophysiological responses of cyclists using the VRC.
Methods: Participants were asked to cycle for 20 min at 30% of their maximum exercise load under four conditions: (1) bicycle ergometer without VR (control), (2) VRC at normal visual flow velocity (VRC-normal), (3) VRC at 0.5 times the visual flow velocity of VRC-normal (VRC-slow), and (4) VRC at 1.5 times the visual flow velocity of VRC-normal (VRC-fast). The order of the four conditions was randomized in a counterbalanced design. The heart rate and rating of perceived exertion were recorded during the exercise. Participants graded their enjoyment of the task using the physical activity enjoyment scale (PACES). The measured data were analyzed by comparing the visual flow velocity conditions (VRC-slow, VRC-normal, and VRC-fast), and comparing the VRC and bicycle ergometer (VRC-normal and control).
Results: A total of 24 participants were enrolled in the study. There was a significant main effect observed in the PACES score (F=20.129, p<0.001, partial η=0.467). In the post-hoc test for the PACES, significant differences were found in the following combinations: VRC-normal > VRC-slow (p=0.005); VRC-fast > VRC-normal (p=0.003); and VRC-fast > VRC-slow (p<0.001). In the modified Borg scale for lower-limb fatigue, there were significant differences in time factor (F=134.048, p<0.001, partial η=0.854) and interaction effects (F=3.156, p=0.018, partial η=0.121). In the post-hoc test for the modified Borg scale, significant trends were found in the following combinations: VRC-normal > VRC-fast (p=0.068) and VRC-slow > VRC-fast (p=0.083).
Conclusion: The results suggest that a slower visual flow velocity may reduce the enjoyment of exercise, whereas a faster visual flow velocity may make the exercise feel less fatigued and more enjoyable.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11247245 | PMC |
http://dx.doi.org/10.7759/cureus.62397 | DOI Listing |
Sci Rep
January 2025
University of Ulsan, 93 Daehak-ro, Nam-gu, Ulsan, 680-749, Republic of Korea.
This study employed large eddy simulation (LES) with the wall-adapting local eddy-viscosity (WALE) model to investigate transitional flow characteristics in an idealized model of a healthy thoracic aorta. The OpenFOAM solver pimpleFoam was used to simulate blood flow as an incompressible Newtonian fluid, with the aortic walls treated as rigid boundaries. Simulations were conducted for 30 cardiac cycles and ensemble averaging was employed to ensure statistically reliable results.
View Article and Find Full Text PDFJ Vasc Interv Radiol
January 2025
Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine. 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan.
Purpose: This research aimed to develop and assess a Lipiodol Pickering emulsion containing anti-Programmed cell Death Ligand 1 (PD-L1) antibodies through in vitro experiments.
Materials And Methods: The emulsion was created by combining Lipiodol with poly (lactic-co-glycolic acid) (PLGA) nanoparticles and anti-PD-L1 antibodies. Confocal laser microscopy was used to evaluate the encapsulation of the antibodies within the Pickering emulsion.
Talanta
January 2025
School of Medical Laboratory, Hunan University of Medicine, Hunan, 418000, China. Electronic address:
Rapid and accurate detection of Chlamydia psittaci, the causative agent of psittacosis, is crucial for both human and animal health but presents significant challenges, particularly in grassroots health institutions. Our previous PDTCTR fluorescence sensing platform, which combined the engineered Cas12f1_ge4.1 system with recombinase polymerase amplification (RPA), significantly enhanced detection efficiency.
View Article and Find Full Text PDFSTAR Protoc
January 2025
Heinz-Nixdorf-Chair of Biomedical Electronics, TranslaTUM, School of Computation, Information and Technology, TUM, Germany; Munich Institute of Biomedical Engineering, TUM, Germany. Electronic address:
Blood cell aggregates are clinically useful biomarkers in a number of medical disorders. This protocol provides accurate and quantitative analysis of cell aggregates using a small volume of whole blood and imaging flow cytometry. We describe steps for sample collection, staining, and measurement.
View Article and Find Full Text PDFJ Cereb Blood Flow Metab
January 2025
Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.
Hyperpolarized-C magnetic resonance imaging (HP-C MRI) was used to image changes in C-lactate signal during a visual stimulus condition in comparison to an eyes-closed control condition. Whole-brain C-pyruvate, C-lactate and C-bicarbonate production was imaged in healthy volunteers (N = 6, ages 24-33) for the two conditions using two separate hyperpolarized C-pyruvate injections. BOLD-fMRI scans were used to delineate regions of functional activation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!