Neuromonitoring during Endovascular Thoracoabdominal Aortic Aneurysm Repair: A Systematic Review.

Ann Vasc Surg

Division of Vascular and Endovascular Surgery, Department of Clinical Surgical and Health Sciences, University of Trieste, Italy.

Published: December 2024

Background: Spinal cord ischemia (SCI) is a potentially devastating complication of thoracic endovascular aortic repair (TEVAR) and fenestrated-branched endovascular aortic repair (F-BEVAR). The aim of this systematic review was to evaluate the efficacy of neuromonitoring modalities to mitigate the risk of SCI during TEVAR and F-BEVAR procedures.

Methods: Following the PRISMA guidelines, we conducted a detailed literature search of databases including PubMed, MEDLINE via Ovid, Embase, Scopus, and Cochrane CENTRAL, from 1998 to the present. Inclusion criteria were original research articles examining neuromonitoring during TEVAR and F-BEVAR. The primary outcome was the incidence of SCI, while the secondary outcome included early mortality. The quality of studies was assessed using the Newcastle-Ottawa Scale.

Results: From 1,450 identified articles, 11 met inclusion criteria, encompassing data from 1,069 patients. Neuromonitoring modalities included motor-evoked potentials (MEPs), somatosensory evoked potentials (SSEPs), and near-infrared spectroscopy. The combination of MEPs and SSEPs was most commonly used, with 93% sensitivity and 96% specificity for detecting SCI risks. SCI incidence ranged from 3.8 to 17.3%, with permanent deficits occurring in 2.7-5.8% of cases. In-hospital mortality ranged from 0.4 to 8%. Risk factors for SCI were identified, including operation duration and extent of aortic coverage.

Conclusions: Neuromonitoring with MEPs and SSEPs appears to be effective in detecting perioperative SCI risk during TEVAR and F-BEVAR. However, discrepancies between neuromonitoring changes and actual SCI outcomes suggest the need for cautious interpretation. While the incidence of SCI remains variable, identified risk factors may guide clinical decisions, particularly in high-risk procedures. Future research should focus on prospective studies and randomized controlled trials to validate these findings and improve SCI prevention strategies in TEVAR and F-BEVAR.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.avsg.2024.06.012DOI Listing

Publication Analysis

Top Keywords

tevar f-bevar
16
sci
10
systematic review
8
endovascular aortic
8
aortic repair
8
neuromonitoring modalities
8
inclusion criteria
8
incidence sci
8
meps sseps
8
risk factors
8

Similar Publications

Objective: To investigate which preoperative factors most impact the 5-year survival of patients undergoing fenestrated/branched endovascular aortic repair (F/BEVAR) and to identify modifiable elements that, if time allows, should be actively managed and adequately controlled preoperatively.

Methods: Patients treated for aortic aneurysms with complex anatomy using either patient-specific company-manufactured or off-the-shelf F/BEVAR devices were included. The exposure of interest was aneurysm type (group I: type I-III thoracoabdominal aneurysms vs group II: type IV thoracoabdominal aneurysms vs group III: juxtarenal or suprarenal aneurysms), and the primary outcome was 5-year risk of all-cause mortality.

View Article and Find Full Text PDF

For high-risk patients with complex aortic aneurysms and post-dissection aneurysms, fenestrated and branched endovascular aortic repair (F/BEVAR) offers minimally invasive options customized to each individual's anatomy. Company-manufactured devices or physician-modified endovascular grafts performed under the purview of an investigational device exemption are two United States Food and Drug Administration-approved avenues to perform fenestrated and branched endovascular aortic repair. This case report describes a creative use of physician-modified endograft to salvage renal function in a solitary kidney with a near immediate bifurcation of the renal artery in a patient with post-dissection extent II thoracoabdominal aortic aneurysm.

View Article and Find Full Text PDF

Background: Multicenter studies conducted in developed countries demonstrated that custom-made devices are safe, effective, and durable for treating complex abdominal aneurysms. However, the situation in developing countries, such as Brazil, is different. Funding and time to have the endoprosthesis delivered are the major concerns.

View Article and Find Full Text PDF

Purpose: This study aims to assess the safety and efficacy of the fenestrated Anaconda device for the treatment of complex aortic aneurysms over 1 year in daily clinical practice.

Materials And Methods: All patients who received the graft between October 2019 and October 2020 were prospectively enrolled in an observational, multicenter national registry. The primary endpoint was the aneurysm-related 1-year mortality rate.

View Article and Find Full Text PDF

Objective: Despite the increasing number of fenestrated and branched endovascular aortic repair (F/B-EVAR) procedures, evidence on post-operative antiplatelet therapy is very limited. This study aimed to investigate the role of single antiplatelet therapy (SAPT) vs. double antiplatelet therapy (DAPT) after F/B-EVAR in 30 day and follow up outcomes.