Purpose: To compare the objective visual quality of moderate-to-high myopia corrected by small incision lenticule extraction (SMILE) and transepithelial photorefractive keratectomy (TransPRK) at a 1,050-Hz ablation frequency, assisted by Smart-Pulse technology (SCHWIND eye-tech-solutions).
Methods: This study involved 123 patients (123 eyes) with moderate-to-high myopia between July 2020 and January 2021. They were categorized into the SMILE group (67 patients, 67 eyes) and the TransPRK group (56 patients, 56 eyes). Follow-ups were conducted at 6 months postoperatively to record the logarithm of the minimum angle of resolution visual acuity, and the Strehl ratio and higher order aberrations were measured using the Sirius anterior segment analysis device (SCHWIND eye-tech-solutions) under a 6-mm pupil diameter at various postoperative intervals.
Results: At 1 week and 1 month postoperatively, the uncorrected distance visual acuity (UDVA) in the SMILE group was superior to that in the TransPRK group ( < .05 for both). At 1 week and 1 month postoperatively, the Strehl ratio value in the SMILE group was higher than that in the TransPRK group ( < .05 for both). At 1, 3, and 6 months postoperatively, coma was greater in the SMILE group than in the TransPRK group ( < .05 for all). Spherical aberrations were lower in the SMILE group than in the TransPRK group at 3 and 6 months postoperatively ( < .05). At 6 months postoperatively, UDVA was -0.09 ± 0.08 and -0.11 ± 0.05 logMAR in the SMILE and TransPRK groups, respectively, which exceeded their preoperative corrected distance visual acuity of -0.05 ± 0.04 and -0.09 ± 0.08 logMAR (all < .001). Compared with preoperative values, the Strehl ratio, total higher order, coma, and spherical aberration differences were significantly increased postoperatively in both groups (all < .001).
Conclusions: Both surgical methods improved UDVA and each had its advantages. The visual quality of SMILE was superior at 1 week and 1 month postoperatively (Strehl ratio values were higher than those of the TransPRK group), and its spherical aberration was lower than that of the TransPRK group at 3 and 6 months; TransPRK with SmartPulse technology with a 1,050-Hz ablation frequency showed that coma was significantly lower than that of the SMILE group at 1, 3, and 6 months postoperatively. .
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3928/1081597X-20240514-01 | DOI Listing |
Oman J Ophthalmol
October 2024
Ophthalmology Resident, King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia.
Purpose: The purpose of this study was to compare early visual outcomes, epithelial healing, and stromal haze between transepithelial photorefractive keratectomy (Trans-PRK) using smart pulse technology (SPT) with traditional Trans-PRK.
Methodology: This study is a retrospective, comparative study conducted at a private eye center in "Riyadh, Saudi Arabia," investigating myopic patients who underwent either Trans-PRK with SPT (study group) or traditional Trans-PRK (control group). The patients were assessed preoperatively and followed up at 1 week and 2 months postoperatively.
Clin Ophthalmol
October 2024
Anterior Segment Department, Miranza Begitek, Donostia-San Sebastián, Spain.
Purpose: To compare corneal aberrometry, densitometry, and refractive outcomes of single-step Transepithelial Photorefractive Keratectomy (Trans-PRK) with and without epithelial thickness customization.
Patients And Methods: This was a prospective, interventional, randomized controlled study. Patients undergoing Trans-PRK using the WaveLight EX500 laser with StreamLight software (Alcon Laboratories, Forth Worth, TX, USA) were randomly assigned to control (55 µm standard epithelial thickness) or customized (thinnest point of epithelial thickness for each patient) groups.
Purpose: To compare haze and refractive outcomes in patients undergoing combined accelerated corneal cross-linking (A-CXL) and selective wavefront-guided transepithelial photorefractive keratectomy (WG-transPRK) without mitomycin C (MMC) versus those undergoing A-CXL.
Methods: This prospective study analyzed 95 eyes (86 patients) with progressive keratoconus from October 2018 to October 2022. The first group underwent CXL combined with corneal or ocular WG-transPRK (CXL+PRK, n = 52), targeting higher order aberrations (HOAs).
Purpose: To compare the objective visual quality of moderate-to-high myopia corrected by small incision lenticule extraction (SMILE) and transepithelial photorefractive keratectomy (TransPRK) at a 1,050-Hz ablation frequency, assisted by Smart-Pulse technology (SCHWIND eye-tech-solutions).
Methods: This study involved 123 patients (123 eyes) with moderate-to-high myopia between July 2020 and January 2021. They were categorized into the SMILE group (67 patients, 67 eyes) and the TransPRK group (56 patients, 56 eyes).
Int Ophthalmol
June 2024
Department of Ophthalmology, Poostchi Ophthalmology Research Center, School of Medicine, Shiraz University of Medical Sciences, Poostchi Clinic, Zand Street, Shiraz, 7134997446, Iran.