A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Effects of Unitizing Nail-Plate Constructs in Distal Femur Fractures: A Biomechanical Study. | LitMetric

Objectives: To assess the biomechanical differences between linked and unlinked constructs in young and osteoporotic cadavers in addition to osteoporotic sawbones.

Methods: Intraarticular distal femur fractures with comminuted metaphyseal regions were created in three young matched pair cadavers, three osteoporotic matched pair cadavers, and six osteoporotic sawbones. Precontoured distal femur locking plates were placed in addition to a standardized retrograde nail, with unitized constructs having one 4.5 mm locking screw placed distally through the nail. Nonunitized constructs had seven 4.5 mm locking screws placed through the plate around the nail, with one 5 mm distal interlock placed through the nail alone. Cadaveric specimens were subjected to axial fatigue loads between 150 and 1500 N (R Ratio = 10) with 1 Hx frequency for 10,000 cycles. Sawbones were axially loaded at 50% of the ultimate load for fatigue testing to achieve runout, with testing performed with 30 and 300 N (R Ratio = 10) loads with 1 Hz frequency for 10,000 cycles.

Results: In young cadavers, there was no difference in the mean cyclic displacement of the unitized constructs (1.51 ± 0.62mm) compared to the non-unitized constructs (1.34 ± 0.47mm) (Figure 4A), (p = 0.722). In osteoporotic cadavers, there was no difference in the mean cyclic displacement of the unitized constructs (2.46 ± 0.47mm) compared to the non-unitized constructs (2.91 ± 1.49mm) (p =0.639). There was statistically no significant difference in cyclic displacement between the unitized and non-unitized groups in osteoporotic sawbones(p = 0.181).

Conclusions: Linked constructs did not demonstrate increased axial stiffness or decreased cyclical displacement in comparison to unlinked constructs in young cadaveric specimens, osteoporotic cadaveric specimens, or osteoporotic sawbones.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BOT.0000000000002839DOI Listing

Publication Analysis

Top Keywords

distal femur
12
unitized constructs
12
cadaveric specimens
12
difference cyclic
12
cyclic displacement
12
displacement unitized
12
constructs
10
femur fractures
8
unlinked constructs
8
constructs young
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!