Quantum dots, also known as semiconductor nanocrystals, are novel fluorescent labels for biological imaging and sensing. However, quantum dot-antibody conjugates with small dimensions (~10 nm), prepared through laborious purification procedures, exhibit limited sensitivity in detecting certain trace disease markers using lateral flow immunoassay strips. Herein, we present a method for the preparation of quantum dot nanobeads (QDNB) using a one-step emulsion evaporation method. Using the as-prepared QDNB, a fluorescent lateral flow immunoassay was fabricated to detect disease biomarkers using C-reactive protein (CRP) as an example. Unlike single quantum dot nanoparticles, quantum dot nanobead-antibody conjugates are more sensitive as immunoassay labels due to signal amplification by encapsulating hundreds of quantum dots in one polymer composite nanobead. Moreover, the larger size of QDNBs facilitates easier centrifugation separation when conjugating QDNBs with antibodies. The fluorescent lateral flow immunoassay based on QDNBs was fabricated, and the CRP concentration in the sample was measured in 15 min. The test results can be qualitatively assessed under UV light illumination and quantitatively measured using a fluorescent reader within 15 min.

Download full-text PDF

Source
http://dx.doi.org/10.3791/67000DOI Listing

Publication Analysis

Top Keywords

lateral flow
16
flow immunoassay
16
fluorescent lateral
12
quantum dots
12
quantum dot
12
immunoassay based
8
quantum
7
fluorescent
5
immunoassay
5
flow
4

Similar Publications

Pseudorabies virus (PRV) is one of the most important infectious diseases which leads to significant economic losses in the global swine industry. The gE-deleted vaccine is widely used to prevent susceptible pigs from PRV infection. There is no report of the differentiation of PRV wild strain and vaccine strain by recombinase polymerase amplification (RPA) coupled with a lateral flow dipstick (LFD) method.

View Article and Find Full Text PDF

Popliteal artery entrapment syndrome has congenital and functional causes. It mostly affects young people. There are six types of popliteal artery entrapment syndrome.

View Article and Find Full Text PDF

Sensitivity-enhanced competitive lateral flow immunoassays by polycaprolactone electrospun stacking pad: Estrous determination in whole blood.

Biosens Bioelectron

December 2024

Nanobiointeractions&Nanodiagnostics, Istituto Italiano di Tecnologia (IIT), Via Morego, 30, 16163, Genova, Italy. Electronic address:

Lateral flow assays (LFA) are widely adopted in point-of-care diagnostics across a spectrum of applications, due to their simplicity of use and cost-effectiveness. However, in complex biological matrices (e.g.

View Article and Find Full Text PDF

Development of a dual-mode lateral flow assay based on structure-guided aptamers for the detection of capsaicin in gutter oils.

Biosens Bioelectron

December 2024

Teaching and Research Office of Food Safety, School of Public Course, Bengbu Medical College, Bengbu, 233000, China. Electronic address:

The construction of structure-guided aptamers and the ultra-sensitive aptamer-based lateral flow assays (Apt-LFA) integrated detection method hold significant potential for food analysis. Using an engineered modified sequence strategy, we successfully developed the aptamer Cap-1-2M4, significantly enhancing its affinity for capsaicin (CAP) to 0.6197 ± 0.

View Article and Find Full Text PDF

Aflatoxin Contamination of Various Staple Foods from Angola and Mozambique.

Toxins (Basel)

November 2024

CIMO, LA SusTEC, Instituto Politécnico de Bragança, Campus de Santa Apolónia, 5300-253 Bragança, Portugal.

Aflatoxins constitute a significant risk in staple foods produced in African countries. This research aimed to analyze the total aflatoxin (AFT) contamination of various staple foods in Angola and Mozambique. A total of 233 samples of corn, peanuts, beans, rice, and cassava flour collected from farmers or local markets from the province of Cuanza Sul, Angola, and the provinces of Gaza and Inhambane, South Mozambique, were analyzed for the presence of AFT using the lateral flow strip method via AgraStrip Pro WATEX (Romer).

View Article and Find Full Text PDF