Background: Cataract surgery has evolved over the years. This study aims to highlight the profile of the patients that underwent cataract surgery at a tertiary hospital with emphasis on patient demographics, surgical techniques performed, intraocular lens powers implanted, and the complications managed.

Methodology: A retrospective cross-sectional descriptive study of all patients who had undergone cataract surgery within two years at the National Eye Centre, Kaduna, Nigeria. Data extracted from the electronic version of the manual cataract surgical records included the patient's age, sex, comorbidities, technique of cataract surgery performed, the intraocular lens powers implanted, and complications encountered. Intraoperative and postoperative complications up to the twelfth week were considered. All patients had biometry-guided intraocular lens implantation.

Results: One thousand four hundred and seventy- two (1,472) patient records of all ages met the inclusion criteria with a male-female ratio of 1.4:1. The mean age was 51.4 ± 22.6 years. The difference in the mean age of the sexes was statistically significant (p=0.01) and 95% CI was 7.37- 10.40 years. Glaucoma was the commonest ocular comorbidity 142(9.65%) and only 5% (74) had systemic comorbidities. The mean intraocular lens (IOL) power was 19.25 ± 1.8Diopters (Range 10.5D to 26D). The commonest surgery performed was small incision cataract extraction with posterior chamber intraocular lens implant (SICS + PCIOL) 91.2% followed by Trabeculectomy with SICS + PCIOL (3.87%). Phacoemulsification accounted for 2.72% of surgeries. Intra-operative complications were posterior capsular rent in 7.1% (104) and vitreous loss in 4% (58). The commonest post-operative complications were corneal edema6.9% (103) and striae keratopathy 4.6% (68).

Conclusion: Most cataract patients were male, above 50years of age and likely to be older than the females at surgery. The most performed surgical technique was small incision cataract surgery with posterior chamber intraocular lens implantation (SICS + PCIOL) while the mean intra-ocular lens power was 19.25 ± 1.8Dioptres. Globally accepted cataract surgical techniques utilizing recent technological advancements were employed with biometry-guided intraocular lens power calculation and implantation. Complications fell within the accepted global rates.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11240202PMC
http://dx.doi.org/10.60787/nmj-v65i2-379DOI Listing

Publication Analysis

Top Keywords

intraocular lens
28
cataract surgery
20
cataract surgical
12
surgery performed
12
sics pciol
12
cataract
9
national eye
8
eye centre
8
centre kaduna
8
kaduna nigeria
8

Similar Publications

Background: Large language models have shown remarkable efficacy in various medical research and clinical applications. However, their skills in medical image recognition and subsequent report generation or question answering (QA) remain limited.

Objective: We aim to finetune a multimodal, transformer-based model for generating medical reports from slit lamp images and develop a QA system using Llama2.

View Article and Find Full Text PDF

Purpose Of The Review: In recent years, Berger's space (BS), the potential space between the posterior lens capsule and the anterior hyaloid membrane, has received little attention from the ophthalmic clinical community. This is primarily due to the limited documentation, with only a few isolated case reports detailing foreign bodies in this area.

Recent Findings: Recent advances in medical imaging technology have enabled the visualization of the BS under various circumstances.

View Article and Find Full Text PDF

Purpose: To evaluate long-term anatomical and functional outcomes in eyes undergoing scleral fixation of aniridic black diaphragm intraocular lens (BDIOL).

Methods: Total 38 eyes that underwent scleral fixation of BDIOL for secondary aniridia following ocular trauma with aphakia with absent posterior capsule or primary congenital aniridia with subluxated lens were retrospectively analyzed. Final visual acuity, early and late complications were examined.

View Article and Find Full Text PDF

Photic phenomena are more pronounced in presbyopia-corrected than in monofocal intraocular lens (IOL), causing dissatisfaction after cataract surgery. Photic Phenomena Test (PPT) quantifies photic phenomena in eyes with two types of presbyopia-corrected IOL. We examined the relationship between preoperative eye shape and pupil diameter.

View Article and Find Full Text PDF

A lensless compact arrangement based on digital in-line holography under Gabor's regime is proposed as a novel contactless method to assess the profile of multifocal intraocular lenses (MIOLs) which are conformed by several diffractive rings. Diffractive MIOLs are a widely adopted ophthalmologic option for the correction of presbyopia in patients undergoing cataract surgery. The MIOL optical design might introduce non-negligible optical performance differences between lenses as well as the introduction of undesirable photic phenomena (such as halos and glare) affecting the vision of users.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!