Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Bipolar electrochemical microscopy (BEM), which visualizes the concentration distribution of molecular species in biological systems by electrochemiluminescence (ECL), is expected to be applied to the high-spatiotemporal-resolution imaging of biomolecules, enabling the analysis of cellular functions. In the past, the molecular species that could be imaged by BEM were generally restricted to oxidized molecules due to the limitation derived from the ECL mechanism of the luminophore. Recently, the imaging of dopamine (DA), a reduced molecule, was achieved using Ru (bpy)/glutathione disulfide (GSSG) as a cathodic luminophore. However, a large driving voltage was required for ECL generation, resulting in a low S/N ratio. In this study, we employed N,N'-dimethyl-3,4,9,10-perylenetetracarboxylic diimide (PDI-CH)/potassium peroxodisulfate (KSO), which is a cathodic luminophore that can be reduced at a nobler potential to produce ECL than [Ru(bpy)]/GSSG. First, the ECL mechanism of PDI-CH/KSO was elucidated by using a PDI-CH drop-cast glassy carbon electrode (GCE) immersed in KSO solution as the working electrode in a 3-electrode system. The PDI-CH drop-casted GCE, a single closed bipolar electrode (c-BPE), was used as the cathode in the successful quantification of 50-500 μmol L DA in a sample chamber in which a c-BPE anode was immersed, resulting in a high S/N. The selective detection of DA in the presence of ascorbic acid was achieved by modifying the anode with Nafion. Finally, DA imaging was demonstrated using a commercially available anisotropic conducting film with PDI-CH coating on the cathode surface as a c-BPE array. The change in the concentration distribution in the inflow of DA was successfully imaged based on the change in the ECL intensity at the c-BPE cathode. This BEM system is expected to be useful for DA imaging of the brain.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.talanta.2024.126509 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!