A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Novel Method for Angiographic Contrast-Based Diagnosis of Stenosis in Coronary Artery Disease: In Vivo and In Vitro Analyses. | LitMetric

A Novel Method for Angiographic Contrast-Based Diagnosis of Stenosis in Coronary Artery Disease: In Vivo and In Vitro Analyses.

Diagnostics (Basel)

Division of Cardiology, Department of Internal Medicine, School of Medicine, Jeju National University, Jeju 63241, Republic of Korea.

Published: July 2024

Background: The existing diagnostic methods for coronary artery disease (CAD), such as coronary angiography and fractional flow reserve (FFR), have limitations regarding their invasiveness, cost, and discomfort. We explored a novel diagnostic approach, coronary contrast intensity analysis (CCIA), and conducted a comparative analysis between it and FFR.

Methods: We used an in vitro coronary-circulation-mimicking system with nine stenosis models representing various stenosis lengths (6, 18, and 30 mm) and degrees (30%, 50%, and 70%). The angiographic brightness values were analyzed for CCIA. The in vivo experiments included 15 patients with a normal sinus rhythm. Coronary angiography was performed, and arterial movement was tracked, enabling CCIA derivation. The CCIA values were compared with the FFR ( = 15) and instantaneous wave-free ratio (iFR; = 11) measurements.

Results: In vitro FFR showed a consistent trend related to the length and severity of stenosis. The CCIA was related to stenosis but had a weaker correlation with length, except for with 70% stenosis (6 mm: 0.82 ± 0.007, 0.68 ± 0.007, 0.61 ± 0.004; 18 mm: 0.78 ± 0.052, 0.69 ± 0.025, 0.44 ± 0.016; 30 mm: 0.80 ± 0.018, 0.64 ± 0.006, 0.40 ± 0.026 at 30%, 50%, and 70%, respectively). In vitro CCIA and FFR were significantly correlated (R = 0.9442, < 0.01). The in vivo analysis revealed significant correlations between CCIA and FFR (R = 0.5775, < 0.05) and the iFR ( = 11, R = 0.7578, < 0.01).

Conclusions: CCIA is a promising alternative for diagnosing stenosis in patients with CAD. The initial in vitro validation and in vivo confirmation in patients demonstrate the feasibility of applying CCIA during coronary angiography. Further clinical studies are warranted to fully evaluate the diagnostic accuracy and potential impact of CCIA on CAD management.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11241538PMC
http://dx.doi.org/10.3390/diagnostics14131429DOI Listing

Publication Analysis

Top Keywords

coronary angiography
12
ccia
10
coronary artery
8
artery disease
8
30% 50%
8
50% 70%
8
ccia ffr
8
stenosis
7
coronary
6
vitro
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!