Computer-Vision-Oriented Adaptive Sampling in Compressive Sensing.

Sensors (Basel)

Graduate School of Information Science and Technology, Osaka University, Osaka 5650871, Japan.

Published: July 2024

Compressive sensing (CS) is recognized for its adeptness at compressing signals, making it a pivotal technology in the context of sensor data acquisition. With the proliferation of image data in Internet of Things (IoT) systems, CS is expected to reduce the transmission cost of signals captured by various sensor devices. However, the quality of CS-reconstructed signals inevitably degrades as the sampling rate decreases, which poses a challenge in terms of the inference accuracy in downstream computer vision (CV) tasks. This limitation imposes an obstacle to the real-world application of existing CS techniques, especially for reducing transmission costs in sensor-rich environments. In response to this challenge, this paper contributes a CV-oriented adaptive CS framework based on saliency detection to the field of sensing technology that enables sensor systems to intelligently prioritize and transmit the most relevant data. Unlike existing CS techniques, the proposal prioritizes the accuracy of reconstructed images for CV purposes, not only for visual quality. The primary objective of this proposal is to enhance the preservation of information critical for CV tasks while optimizing the utilization of sensor data. This work conducts experiments on various realistic scenario datasets collected by real sensor devices. Experimental results demonstrate superior performance compared to existing CS sampling techniques across the STL10, Intel, and Imagenette datasets for classification and KITTI for object detection. Compared with the baseline uniform sampling technique, the average classification accuracy shows a maximum improvement of 26.23%, 11.69%, and 18.25%, respectively, at specific sampling rates. In addition, even at very low sampling rates, the proposal is demonstrated to be robust in terms of classification and detection as compared to state-of-the-art CS techniques. This ensures essential information for CV tasks is retained, improving the efficacy of sensor-based data acquisition systems.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11244518PMC
http://dx.doi.org/10.3390/s24134348DOI Listing

Publication Analysis

Top Keywords

compressive sensing
8
sensor data
8
data acquisition
8
sensor devices
8
existing techniques
8
detection compared
8
sampling rates
8
sampling
6
sensor
5
data
5

Similar Publications

Aims: The aim of this study was to develop an ultra-short echo time 3D magnetic resonance imaging (MRI) method for imaging subacute myocardial infarction (MI) quantitatively and in an accelerated way. Here, we present novel 3D T- and T -weighted Multi-Band SWeep Imaging with Fourier Transform and Compressed Sensing (MB-SWIFT-CS) imaging of subacute MI in mice hearts .

Methods And Results: Relaxation time-weighted and under-sampled 3D MB-SWIFT-CS MRI were tested with manganese chloride (MnCl) phantom and mice MI model.

View Article and Find Full Text PDF

Purpose: To develop a rapid, high-resolution and distortion-free quantitative $R_{2}^{*}$ mapping technique for fetal brain at 3 T.

Methods: A 2D multi-echo radial FLASH sequence with blip gradients is adapted for fetal brain data acquisition during maternal free breathing at 3 T. A calibrationless model-based reconstruction with sparsity constraints is developed to jointly estimate water, fat, $R_{2}^{*}$ and $B_{0}$ field maps directly from the acquired k-space data.

View Article and Find Full Text PDF

Compressive electron backscatter diffraction imaging.

J Microsc

January 2025

Department of Mechanical, Materials and Aerospace Engineering, University of Liverpool, Liverpool, UK.

Electron backscatter diffraction (EBSD) has developed over the last few decades into a valuable crystallographic characterisation method for a wide range of sample types. Despite these advances, issues such as the complexity of sample preparation, relatively slow acquisition, and damage in beam-sensitive samples, still limit the quantity and quality of interpretable data that can be obtained. To mitigate these issues, here we propose a method based on the subsampling of probe positions and subsequent reconstruction of an incomplete data set.

View Article and Find Full Text PDF

Transferring knowledge learned from standard GelSight sensors to other visuotactile sensors is appealing for reducing data collection and annotation. However, such cross-sensor transfer is challenging due to the differences between sensors in internal light sources, imaging effects, and elastomer properties. By understanding the data collected from each type of visuotactile sensors as domains, we propose a few-sample-driven style-to-content unsupervised domain adaptation method to reduce cross-sensor domain gaps.

View Article and Find Full Text PDF

Today, huge amounts of time series data are sensed continuously by AIoT devices, transmitted to edge nodes, and to data centers. It costs a lot of energy to transmit these data, store them, and process them. Data compression technologies are commonly used to reduce the data size and thus save energy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!