Enhancing Micro-Raman Spectroscopy: A Variable Spectral Resolution Instrument Using Zoom Lens Technology.

Sensors (Basel)

Laboratory for Molecular Physics and Synthesis of New Materials, Ruđer Bošković Institute, Bijenička Cesta 54, 10000 Zagreb, Croatia.

Published: July 2024

Raman spectroscopy is a powerful analytical technique based on the inelastic scattering of photons. Conventional macro-Raman spectrometers are suitable for mass analysis but often lack the spatial resolution required to accurately examine microscopic regions of interest. For this reason, the development of micro-Raman spectrometers has been driven forward. However, even with micro-Raman spectrometers, high resolution is required to gain better insight into materials that provide low-intensity Raman signals. Here, we show the development of a micro-Raman spectrometer with implemented zoom lens technology. We found that by replacing a second collimating mirror in the monochromator with a zoom lens, the spectral resolution could be continuously adjusted at different zoom factors, i.e., high resolution was achieved at a higher zoom factor and lower spectral resolution was achieved at a lower zoom factor. A quantitative analysis of a micro-Raman spectrometer was performed and the spectral resolution was analysed by FWHM using the Gaussian fit. Validation was also performed by comparing the results obtained with those of a high-grade laboratory Raman spectrometer. A quantitative analysis was also performed using the ANOVA method and by assessing the signal-to-noise ratio between the two systems.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11243961PMC
http://dx.doi.org/10.3390/s24134284DOI Listing

Publication Analysis

Top Keywords

spectral resolution
16
zoom lens
12
lens technology
8
resolution required
8
development micro-raman
8
micro-raman spectrometers
8
high resolution
8
micro-raman spectrometer
8
resolution achieved
8
zoom factor
8

Similar Publications

Background: To define optimal parameters for the evaluation of vessel visibility in intracranial stents (ICS) and flow diverters (FD) using photon-counting detector computed tomography angiography (PCD-CTA) with spectral reconstructions.

Methods: We retrospectively analyzed consecutive patients with implanted ICS or FD, who received a PCD-CTA between April 2023 and March 2024. Polyenergetic, virtual monoenergetic, pure lumen, and iodine reconstructions with different keV levels (40, 60, and 80) and reconstruction kernels (body vascular [Bv]48, Bv56, Bv64, Bv72, and Bv76) were evaluated by two radiologists with regions of interests and Likert scales.

View Article and Find Full Text PDF

AI integration into wavelength-based SPR biosensing: Advancements in spectroscopic analysis and detection.

Anal Chim Acta

March 2025

Artificial Intelligence Research Center, Chang Gung University, Taoyuan, 333323, Taiwan; Department of Artificial Intelligence, College of Intelligent Computing, Chang Gung University, Taoyuan, 333323, Taiwan. Electronic address:

Background: In recent years, employing deep learning methods in the biosensing area has significantly reduced data analysis time and enhanced data interpretation and prediction accuracy. In some SPR fields, research teams have further enhanced detection capabilities using deep learning techniques. However, the application of deep learning to spectroscopic surface plasmon resonance (SPR) biosensors has not been reported.

View Article and Find Full Text PDF

Non-optically active water quality parameters (NAWQPs) are essential for surface water quality assessments, although automated monitoring methods are time-consuming, include labor-intensive chemical pretreatment, and pose challenges for high spatiotemporal resolution monitoring. Advancements in spectroscopic techniques and machine learning may address these issues. We integrated ultraviolet-visible-near infrared absorption spectroscopy with physical-chemical measurements to predict total nitrogen (TN), dissolved oxygen (DO), and total phosphorus (TP) in the Yangtze River Basin, China.

View Article and Find Full Text PDF

Hyperspectral Imaging for High Throughput Optical Spectroscopy of pL Droplets.

Anal Chem

January 2025

Nanophotonic Systems Laboratory, Department of Mechanical and Process Engineering, ETH Zurich, 8092 Zurich, Switzerland.

Droplet-based microfluidics is a powerful tool for high-throughput analysis of liquid samples with significant applications in biomedicine and biochemistry. Nevertheless, extracting content-rich information from single picolitre-sized droplets at high throughputs remains challenging due to the weak signals associated with these small volumes. Overcoming this limitation would be transformative for fields that rely on high-throughput screening, enabling broader multiparametric analysis.

View Article and Find Full Text PDF

Scientific-grade spectrometers with high hyperspectral resolution and high spectral accuracy are desirable in miniaturized optical systems to maintain stable and real-time spectral sampling. Fourier transform spectrometers that utilize high-precision moving mirrors generally struggle to enhance their miniaturization and stable real-time performance. A static infrared spectral measurement method is proposed that uses micro/nano-optical devices as the core of static interference and lightweight imaging.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!