Mechanical Valves: Past, Present, and Future-A Review.

J Clin Med

Department of Cardiothoracic Surgery, Carmel Medical Center, Haifa 3436212, Israel.

Published: June 2024

The mechanical valve was first invented in the 1950s, and since then, a wide variety of prostheses have been developed. Although mechanical valves have outstanding durability, their use necessitates life-long treatment with anticoagulants, which increases the risk of bleeding and thromboembolic events. The current guidelines recommend a mechanical prosthetic valve in patients under 50-60 years; however, for patients aged 50-70 years, the data are conflicting and there is not a clear-cut recommendation. In recent decades, progress has been made in several areas. First, the On-X mechanical valve was introduced; this valve has a lower anticoagulant requirement in the aortic position. Second, a potential alternative to vitamin K-antagonist treatment, rivaroxaban, has shown encouraging results in small-scale trials and is currently being tested in a large randomized clinical trial. Lastly, an innovative mechanical valve that eliminates the need for anticoagulant therapy is under development. We attempted to review the current literature on the subject with special emphasis on the role of mechanical valves in the current era and discuss alternatives and future innovations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11242849PMC
http://dx.doi.org/10.3390/jcm13133768DOI Listing

Publication Analysis

Top Keywords

mechanical valves
12
mechanical valve
12
mechanical
7
valve
5
valves future-a
4
future-a review
4
review mechanical
4
valve invented
4
invented 1950s
4
1950s wide
4

Similar Publications

Bicuspid aortic valve (BAV), the most common congenital cardiac anomaly, predisposes individuals to aortic stenosis and regurgitation due to valve degeneration. Abnormal hemodynamics, arterial wall characteristics, and genetic factors contribute to ascending aorta dilatation, potentially leading to severe complications like aortic dissection. Presently, the most recent guidelines propose that individuals with BAV requiring valve replacement due to valve dysfunction should undergo simultaneous replacement of the ascending aorta when the diameter of aortic dilatation exceeds 4.

View Article and Find Full Text PDF

Region-specific biomechanical characterization of ascending thoracic aortic aneurysm of hypertensive patients with bicuspid aortic valves.

Biomech Model Mechanobiol

December 2024

Institute for Biomedical Engineering and Nano Science, Shanghai East Hospital, Tongji University School of Medicine, 500 Zhennan Road, Shanghai, 200331, People's Republic of China.

Hypertension and bicuspid aortic valve (BAV) are key clinical factors that may affect local biomechanical properties of ascending thoracic aortic aneurysms (ATAAs). This study sought to investigate regional differences in biaxial mechanical properties of the ATAAs for the hypertensive patients with BAV. Fresh ATAA samples were harvested from 16 hypertensive patients (age, 66 ± 9 years) undergoing elective aortic surgery.

View Article and Find Full Text PDF

Purpose: Advancements in minimally invasive technologies to decrease postoperative morbidity and recovery times represent a large opportunity for mitral valve repair operations. However, current technologies are unable to replicate gold standard surgical neochord implantation.

Methods: We developed a novel neochordal repair device, Minimally Invasive Ventricular Anchoring Neochordoplasty (MIVAN), which operates via transcatheter, trans-septal anchoring to the posterior ventricular wall.

View Article and Find Full Text PDF

Methods: In this case report, we present an in-depth narrative of a patient who was subjected to mechanical thrombectomy (MT) for an obstruction in the main trunk and bifurcation of the left middle cerebral artery subsequent to Infective Endocarditis (IE). Initial intervention using a solitary-stent technique proved to be ineffective; thus, we shifted to a dual-stent strategy, which successfully recanalized the compromised blood vessel.

Results: The dual-stent retriever method can be especially advantageous for treating persistent clots that occur at arterial bifurcations resisting the efforts of a single-stent retriever during the MT process.

View Article and Find Full Text PDF

Background And Objective: Deep vein thrombosis (DVT) of the lower limbs is a critical global vascular disease. Accurately assessing and predicting the efficacy of DVT treatment remains a significant challenge due to a lack of understanding of the mechanisms by which the level of patient-specific embolization and the rate of drug injection affect thrombolytic therapy.

Methods: In this study, we used the computed tomographic venography (CTV) clinical method to obtain patient-specific parameters, and the flow-solid interaction (FSI) method combined with biochemical response modeling of thrombolysis to analyze patient-specific hemodynamic and biomechanical characteristics and to quantitatively assess the effects of three vessel embolism levels (VEL) versus two drug injection rates (DIR) on bifurcated femoral venous thrombolytic therapy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!